Cell sensor is dirty.
Clean.
See maintenance.
No water flow
Check the water system
"OVERLOAD"
The cell is incorrectly
connected.
Check wiring.
Metal body in the cell.
Turn off the equipment and
remove the metal body
from the sheets
The 4 production
LEDs
(%)
will
flash.
(Open circuit)
Cell
is
incorrectly
connected.
Check the cell connection
and ensure that cables and
connection terminals are in
good condition.
Cell
is
damaged
or
completely worn down.
Check the condition of the
cell electrodes, and replace
it if any damage is
observed.
Swimming pool water with
very low salt concentration.
Ensure that the water has
salt and that it is dissolved.
4.4- Warning messages and alarms (EVO)
In the event of abnormal operation, the EVO series equipment will display an
alarm
message on the 4th line of the screen, together with an acoustic
warning. The alarms shutdown the equipment until the problem is solved.
Similarly, it will display a
warning
also in the 4th line, but without an acoustic
signal or shutting down the equipment. In this case, the equipment can
continue operating, although you are informed that corrective action should be
taken.
4.4.1- Warnings
Message:
Causes:
Action required:
"LACK OF SALT"
Lack of salt in the water.
Add salt to the swimming pool.
Incrustations or objects in
the electrolysis cell causing
excess current.
Clean the cell.
The electrolysis cell is worn. Replace the electrolysis cell with
a new one.