![BSi IRX-3811 Product Manual Download Page 13](http://html1.mh-extra.com/html/bsi/irx-3811/irx-3811_product-manual_2823448013.webp)
Real Freedom | Receiver Product Manual
13 of 51
3
Installation
This chapter contains the installation instructions for the Real Freedom Receiver.
Before installing and connecting other components to the receiver, you should familiarize yourself with the
Location and functions of parts
, which provides information about the receiver’s front and rear panel
connectors.
Preparation
Before installing the receiver and other components of the system, you should familiarize yourself with the
receiver’s environmental, power and space requirements.
Environmental requirements
The following table summarizes the environmental requirements for the operation and storage of a Real
Freedom Receiver.
Table 1: Environmental specifications
Specification
Details
Humidity
95% non-condensing
Operating and storage temperature
14° to 140°F / -10° to +60°C
Power requirements
The following table summarizes the power requirements for a Real Freedom Receiver.
Table 2: AC and DC power specifications
Specification
Details
AC supply
100
–240 V AC, 50/60 Hz, 5 A
AC supply connector
IEC 60320, C14
DC supply
10
–36 V DC, 10 A
DC supply connector
XLR-4 (M)
Physical requirements
The following table summarizes the physical requirements for a Real Freedom Receiver.
Table 3: Physical specifications
Specification
Details
Size (W x H x D)
8.27 x 3.46 x 13.39 inch / 210 x 88 x 340 mm
(½ rack width, 2RU high)
Weight
8.16 lb. / 3.7 kg