background image

SAVIO PLUS COMBI USER MANUAL

Dear Customer:

Thank you for buying a SAVIO Plus Combi.

The SAVIO Plus Combi is a high ef

fi

 ciency condensing, wall mounted gas boiler which

provides central heat.

We realize that it is not possible to answer all questions about the SAVIO Plus Combi in this 
manual. Reading this installation manual does not make the reader an expert in all aspects 
of installation and operation, and does not replace the need for a quali

fi

 ed, licensed heating 

contractor. We urge you to contact your installing contractor or distributor if you are in question 
about any aspect of your boiler’s performance. Our main concern is that you are satis

fi

 ed with 

your boiler and its performance. We require that your contractor complete ef

fi

 ciency tests using 

instruments.

The external controls and accessories listed in this manual (excluding those supplied inside 
the boiler) are intended to serve as guidelines rather than speci

fi

 c recommendations. We re-

alize that other makes and models of such devices are available and can be used as suc-
cessfully as those we specify. The installing contractor is the best judge of a system’s speci

fi

 c 

requirements, as well as the local availability of certain makes and models of controls and 
accessories. The preceding does not apply, however, to the equipment that comes with every 
boiler, such as the overheat control and pressure relief valves. 

The installation of the spe-

cifi c devices supplied with every boiler is absolutely necessary to the safe operation of 
the boiler and protection of the heating system.

All SAVIO wall hung boilers are built in accordance with the ASME boiler and pressure vessel 
code, and bear the “H” stamp. The Entire range of applications for the SAVIO Plus Combi has 
been tested to standard CSA 4.9 and is CSA compliant.
 
This SAVIO Plus Combi has a 2 year warranty

 on the boiler

and 10 years on the heat exchanger

a copy of which is provided with the boiler. Please be sure to return the warranty registration card as 
the warranty will be void without your 

b

oiler’s serial numbers (located on the ratings label af

fi

 xed to 

the boiler), date of installation and the name of your installer being on record in our 

fi

 les.

Thank you for purchasing our SAVIO Plus Combi. If you have questions or comments, please 
don’t hesitate to contact us immediately. Our goal is 100% customer satisfaction.

BOYERTOWN

Summary of Contents for Savio plus combi

Page 1: ...light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Fol low the gas supplier s instructions If you can...

Page 2: ...installing contractor is the best judge of a system s specific requirements as well as the local availability of certain makes and models of controls and accessories The preceding does not apply howev...

Page 3: ...Operation Lights 4 10 Instructions for Use 5 11 14 Warnings 5 1 11 Refilling Procedure 5 2 11 Lighting Operation Instruction 5 3 12 Central Heating Circuit Temp 5 4 12 13 Extinguishing Instructions 5...

Page 4: ...alified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water Do not store or use gasoline or other flammable vapors and...

Page 5: ...ten confused with those of influenza and the highest incidence of poisoning occurs at the onset of cold weather or during flu season A victim may not experience any symptoms only one symptom or a few...

Page 6: ...boiler area clean and free of all fire hazards Please read the literature and warranties supplied by the manufacturers of the various accessory equipment This equipment is warranted by the respective...

Page 7: ...al frost protection system to prevent frost dam age which can occur in areas susceptible to very cold weather conditions Boiler operation recognition system should the boiler not be used for longer th...

Page 8: ...ressure inwc 0 64 Flue pipe diameter Coaxial in 2 25 4 3 25 5 Twin split pipes in 3 25 3 25 Nominal heat flow rate MBH 116 0 Nominal heat flow rate 2000 4500ft MBH 110 2 Min Exhaust temperature F 120...

Page 9: ...tton 7 Function switch and Central heating tem perature adjustment knob 8 Domestic hot water temperature control knob 9 Appliance operation lights 4 5 6 7 8 9 3 1 2 Figure 3 1 Figure 3 3 Figure 3 2 Pi...

Page 10: ...n Anti freeze system active 1 second pulse every 2 seconds normally operating boiler Function selector in on position Central heating operation Frost protect operation Faulty central heating temperatu...

Page 11: ...h a built in anti freeze system that operates the boiler when the temperature is below 41 F Therefore when the boiler is not lit or used in cold weather with consequent risk of freezing do not switch...

Page 12: ...s operating boiler 4 If the appliance will not operate follow the extinguishing instructions on page 13 and call your service technician or gas supplier Figure 5 2 A B C D E Central Heating Circuit Te...

Page 13: ...F Between 23 and 41 F Lower than 23 F Extinguishing Instructions 5 5 To turn the boiler off set the function selector B to the position shown in the Figure 5 5 The appliance operation light A figure...

Page 14: ...minimum output Where the demand is at a low level or with the temperature set to the minimum it is normal to see a cycle of lighting and extinguishing of the burner when running Regulate the domestic...

Page 15: ...the external temperature may be lower than 32 F it is suggested to leave the system running setting the room thermostat at a low temperature When the boiler is completely switched off for a long perio...

Page 16: ...n and then press the boiler reset button 2 Fig 6 2 For the first light up and following main tenance procedures for the gas supply it may be necessary to repeat the resetting operation several times s...

Page 17: ...that this does not happen and to decrease the pressure to a normal value it is advisable to vent some of the water in the appliance through the bleed valves present in the heating system Figure 6 3 If...

Page 18: ...ight pre paid BOYERTOWN and SAVIO will not be responsible for 1 Components that are part of the heating system but were not manufactured by SAVIO or BOYERTOWN as part of the boiler 2 The workmanship o...

Page 19: ...SAVIO PLUS COMBI USER MANUAL 19...

Page 20: ...17962 1520 0 2908 20A4 USA...