SAFETY RULES 

Follow all electrical and safety codes as well as the National Electrical Code (NEC), National Fire Protection Association (NFPA), and the 

Occupational Safety and Health Act (OSHA). Qualified personnel should perform all electrical connections and wiring only. 

National  Fire  Protection  Association  (NFPA)  standards  require  specific  duct  design  and  dust  collector  configuration  when  collecting 

potentially reactive metal dusts, such as aluminum, magnesium, and other materials.  NFPA also covers other dusts such as grain and 

plastics, etc. A guideline for determining the precautions to be taken can be found in NFPA 497. Other NFPA standards may apply to your 
specific  application.  Consult current  NFPA  standards, available  for NFPA, 1  Batterymarch Park,  Quincy, MA,  02269, 800-344-3555,  for 

applicable safeguards which may be required for the Installation, Operation, and Service of this product. 

Additional references are the Uniform Building Code and the Uniform Mechanical Code. 

DISCLAIMER 

Although instructions and recommendations are included for installation or your mist or dust collector equipment, the manufacturer does not 

assume responsibility for the installation of this equipment nor shall be held liable for direct or consequential damages resulting from improper 

methods, structural failure or inadequate supports. 

WARNING 

1.

Avoid mixing combustible materials such as (but not limited to) buffing lint, paper / wood dust, aluminum or
magnesium with dust generated from the grinding of ferrous materials.  This creates a potential for fire due
to the mixing of sparks and combustible materials.

2.

Under no conditions should the machine operator be allowed to put lit cigarettes or any burning object into
this or any dust/mist control system.

3.

Installation of this unit in applications where there is a chance for heated and/or flammable materials to
enter the unit should be evaluated to determine if a fire protection/extinguishing system should be installed.
Federal, state or local codes, a required by organizations such as NFPA and Factory Mutual Insurance or
your insurance carrier may require such a system. 

B

SE

 can offer basic guidelines for such an installation;

however

4.

Explosion relief vents are required on some applications. Consult with an insurance underwriter or an
NFPA manual to determine proper vent size ratio. Dust or mist collectors must be located outdoors unless
otherwise indicated by NFPA standards. Dust and mist collectors DO NOT CONTAIN EXPLOSION
RELIEF VENTS as shipped from the factory and must be field installed per NFPA standards.

Always use BSE replacement filters - for reordering, please contact 

your dealer or BSE.

WARRANTY INFORMATION

BSE warrants all products sold, only to purchasers for use in business or for resale, against defects in workmanship or materials 

under normal use for one year after date of purchase from BSE. This warranty does include standard warranties from purchased 

parts such as blowers, motors, valves, etc. All purchased items will fall under the manufacturers' standard warranty. Any part 

which is determined to be defective in material or workmanship and returned to BSE or authorized service facility, as BSE 

designates, shipping cost prepaid, will be, as the exclusive remedy, repaired or replaced, at BSE's option. Any liability for 

consequential and incidental damage is expressly disclaimed. BSE liability, in all events, is limited to and shall not exceed, the 

purchase price paid. 

Title and risk of loss pass to buyer on delivery to the common carrier. If product is damaged in transit, recipient must file claim with 

carrier. BSE will make a good faith effort for prompt correction or other adjustments with respect to any product that proves to be 

defective within the warranty period. 

Summary of Contents for Air-Pro Series

Page 1: ...AND MIST CONTROL SYSTEMS AND EQUIPMENT ARE IMPOSSIBLE TO LIST THEREFORE OBTAIN THE SERVICES OF A PROFESSIONAL INSTALLER A FIRE PROTECTION EXPERT SHOULD BE OBTAINED IN THE EVENT THE PRODUCT IS INTENDED...

Page 2: ...ard Curve Four way individually adjustable blades Standard Unit 1 35 Pre Filter and 1 95 Primary Bag Filter 20 x 15 x 24 HEPA Unit 1 35 Pre Filter 1 95 Bag Filter 20 x 15 x 12 and 1 HEPA Filter Pre fi...

Page 3: ...it in applications where there is a chance for heated and or flammable materials to enter the unit should be evaluated to determine if a fire protection extinguishing system should be installed Federa...

Page 4: ...the carton is opened at a later time and there is damage to the unit you should file a concealed damage claim with the delivery carrier They are responsible for any damages in shipment or shortages th...

Page 5: ...Page 5...

Page 6: ...trations It is a complete air filter packaged unit that can be installed easily and used as a free hanging air filter unit to clean the ambient pollutants smoke and haze The BSE AIRPRO glass multi poc...

Page 7: ...ollect your contaminant Media type filters actually become more efficient as they load with contamination However as the filters load up the air flow volume will decrease and eventually will reach a p...

Page 8: ...Page 8 Wiring Diagram...

Page 9: ...pecifications contact your BSE distributor for further assistance TROUBLE SHOOTING Your equipment has been manufactured to quality standards and tested for reliable operation at the factory Proper ope...

Page 10: ...Page 10...

Reviews: