MOTORS
All direct drive motors are protected with automatic restart overload protection.
All belt driven units must be protected externally.
OPERATION
Do not operate your units without filter for more than a few minutes at a time.
MAGNEHELIC PRESSURE GAGE OPTION
This is an option to help determine when to change the filters. As the bags fill with contaminants, the
needle on the gage will rise. We recommend changing the bags between 1.25 1.50 above the reading with
clean filters. It is normal to change the pleated twice (or more) as much as the inside bag filter. After the
pleated has been change and there is no longer a drop in pressure, then it is time to change main filter. The
reading may vary depending upon the contaminants. Please consult your Sales Engineer for further
information.
FILTERS
All units are equipped with replaceable type media filters. In some cases, where contaminants being picked
up are dry, it is possible to wash the prefilters and reuse them. Filters are available in a number of different
degrees of efficiencies. The filters in your new
BSE
unit have been selected by your representative to best
collect your contaminant.
Media type filters actually become more efficient as they load with contamination. However, as the filters
load up, the air flow volume will decrease and eventually will reach a point where they must be replaced to
restore the original air flow. Changing the filters in your new
BSE
air cleaner is easy. Old filters are simply
pulled out of the entrance end of the unit and new filters are installed. No tools are required. Turning the
unit on when installing new filters will help to pull them into place.
GENERAL NOTE: CLEANING AND INSPECTION OF CABINET
After the dirty components have been removed, inspect the cabinet interior. Remove foreign material, wipe
interior, and clean all filter seating surfaces.
When installing new filters, the opening in the bag filter should be in a vertical position. Be sure the cloth
part of the bag does not bunch up between the bag header and the angle iron filter stops on the cabinet.
Replacement filters can be supplied by your representative.
LOUVERS
Four-way louvers are provided on all units to permit you to direct the discharge air away from pilot lights
on heaters and to help you obtain the best air flow pattern for maximum cleaning.
PARTS
ALWAYS USE
BSE
REPLACEMENTS FILTERS & PARTS TO MAINTAIN WARRANTY.
TO ORDER REPLACEMENTS PARTS:
CONTACT
your
BSE dealer.
Page 7