8
GEL: 14.1V
,
AGM/WET: 14.4V
,
Calcium: 14.7V
. If the Battery Condition is still less than 12.5V
after absorption mode, this will be indicated by the GREEN Full Charge LED flashing.
Indicated
by the BLUE Charging LED ON
●
Equalizing
: This stage begins automatically if the Calcium Battery type has been selected. This
cycle pushes the charge voltage up to an equalizing level of 16.2V.
Indicated by the BLUE
Charging LED ON
●
Analysis
: This stage diagnoses the battery condition within ten minutes. If the Full Charge LED is
flashing, this indicates that the battery is still less than 12.5V after the absorption mode and that there
is a fault with the battery.
Indicated by the GREEN Full LED ON
●
Full / Float
: Battery is fully charged and is ready for use. It will be maintained at a safe constant
voltage. Battery type selection:
GEL: 13.4V
AGM/WET: 13.5V
Calcium: 13.6V
Indicated by the GREEN Full Charge LED ON
REJUVENATION PROCESS (EXTEND YOUR BATTERY LIFE)
Your Battery Charger provides battery rejuvenation function.
What does this feature do?
Rejuvenation
has been proven to break down the crystalline
form of lead sulphate within the battery cells which helps extend your battery life.
We recommend that you periodically use this rejuvenation (De-Sulphate) feature to ensure
you get the maximum life out of your battery.
To activate this rejuvenation feature, simply press and hold the ‘Battery Type’ Button for 3
Seconds until the Rejuvenation LED begins flashing (YELLOW).
Once the charger has entered the rejuvenation (de-sulphate) charging stage, the process will
automatically time out after 24 hours or you can manually stop this process at any time by
pressing and holding down the ‘Battery Type’ Button for 3 seconds.
AUTOMATIC EQUALISATION PROCESS (For Calcium Batteries Only)
Your Battery Charger also provides a battery equalisation function.
What does this feature do?
Equalisation
helps to maintain and balance your battery cells by
reversing the high concentration of electrolytes from the bottom of your battery.
This allows all the cells to charge evenly and makes you get the most out of your battery.
You can activate this feature weekly to ensure your battery is always well maintained.
Note: If you select the Calcium battery type, the charger will automatically run the equalisation stage during the charging cycle.
The Equalisation process does not occur for GEL or Sealed/WET Battery Type Selection
.
Depending on the charge rate selected, this process will time out after 1 to 3 hours.