10 

 

 

 

 TROUBLE SHOOTING 

 

Problems

 

Indication

 

Possible causes

 

Suggest solution

 

Charger does 

not work 

Indicator lights are 

not on 

No AC power 

Check AC connections and make   

sure Power Point is switched ON 

 
Charger has 
no DC output 

 
Error LED is ON. 

Output is short circuited 

 

 

Output Reverse polarity connection 

Check DC connection between 

charger and battery and make sure 

they are not short circuiting 

Check that the alligator clips / ring 

terminals are connected to the correct 

polarity 

 

LED CHARGE INDICATION:

 

 

Charging 

Full Charge  Rejuvenation 

Error 

 

(Blue) 

(Green) 

(Yellow) 

(Red) 

A.C. Power connected, battery 

disconnected 

OFF 

OFF 

OFF 

OFF 

Manual Rejuvenation charging 

OFF 

OFF 

FLASH 

OFF 

Soft Start charging 

FLASH 

OFF 

OFF 

OFF 

Bulk charging 

ON 

OFF 

OFF 

OFF 

Absorption charging 

ON 

OFF 

OFF 

OFF 

Equalization charging 

ON 

OFF 

OFF 

OFF 

Analysis mode 

OFF 

ON 

OFF 

OFF 

Float charging with Battery analyze is 

over 12,5V 

OFF 

ON 

OFF 

OFF 

Float charging with Battery analyze is 

below 12,5V 

OFF 

FLASH 

OFF 

OFF 

Output Clip shorted or battery Reserve 

OFF 

OFF 

OFF 

ON 

Battery Condition check, Battery is 

defective 

OFF 

OFF 

OFF 

FLASH 

Soft Start charging 6 hours timed-out 

FLASH 

OFF 

OFF 

FLASH 

Bulk Charging 24 Hours timed-out 

ON 

OFF 

OFF 

FLASH 

Charger over-temperature protected 

OFF 

OFF 

OFF 

FLASH 

 

 

CHARGING CURVE (VOLTAGE): 

Summary of Contents for BS40

Page 1: ...ER For lead acid batteries User Manual and Guide to professional battery charging for Starter and Deep Cycle batteries THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR 12V BATTERY...

Page 2: ...the connections to the battery Connection to supply mains has to be in accordance with National wiring rules Battery acid is corrosive Rinse immediately with water if acid comes into contact with ski...

Page 3: ...put short circuit occurred and prevents any damage Reverse polarity protection The charger can automatically shut off when the output polarity reversed and without damage Never overcharge your battery...

Page 4: ...s as described in this manual SHORT CIRCUIT PROTECTION The charger has reverse battery and short circuit protection If a reverse battery or charger output lead short condition exists Red LED flashes w...

Page 5: ...the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines Check the Voltage Output Switch on the charger and make sure it s on the correct voltage Part Nu...

Page 6: ...icle determine if the vehicle is positively or negatively earthed o If Negatively Earthed Most Common FIRST Connect the Red battery charger lead to the positive Battery post and then connect the Black...

Page 7: ...correct Battery Type is selected Do not charge using an incorrect Battery Type Setting Do not charge a Gel Battery with Calcium Battery selection as this may damage your battery Note The charger will...

Page 8: ...life We recommend that you periodically use this rejuvenation De Sulphate feature to ensure you get the maximum life out of your battery To activate this rejuvenation feature simply press and hold the...

Page 9: ...ossible As they may need topping up with distilled water after charging LED STATUSINIDICATOR TABLE 1 Charging Rate Selection Button Press Mode to Select the Current Charge Rate 2 Charging Current LED...

Page 10: ...ror Blue Green Yellow Red A C Power connected battery disconnected OFF OFF OFF OFF Manual Rejuvenation charging OFF OFF FLASH OFF Soft Start charging FLASH OFF OFF OFF Bulk charging ON OFF OFF OFF Abs...

Page 11: ...ours soft start timer reached 24 hours bulk charge timer reached Check the charging rate and battery type selection matches the battery Battery cannot be charged and must be replaced Abnormal LED indi...

Reviews: