4
| www.bs-battery.com
BATTERY TYPES & CAPACITY
•
Suits all Lead Acid type batteries (Conventional, AGM & Gel).
•
Suits for lithium (LiFePO4) battery.
•
Battery capacity:
Charge rate
Battery capacity - charging
Battery capacity - maintaining
3Amp
4-60Ah
4-120Ah
ELECTRICAL PARTS
Delivered with:
•
Input Cord: 183cm input leads with VDE plug.
•
Output Cord: 122cm with quick connector.
•
Extend Cord: 61cm with battery ring terminal / battery clips.
ENVIRONMENTAL CHARACTERISTICS
•
Operating temperature: 0 to 40° C.
•
Storage temperature: -25 to 85°C.
•
Operating humidity range: 0 to 90% RH.
•
Cooling: natural cooling.
TECHNICAL SPECIFICATIONS
AC input
90~265Vac
Input Frequency
50/60Hz
Rated output
12V 3Amp
Suit for battery type
Compatible for Lead Acid or Lithium (LiFePO4) battery
Power Efficiency
>80%
Charging stage
Multiple – 9 stages
Start voltage
8V
Charging voltage
14.4V
Float voltage – Lead acid battery
13.6V
Maintenance voltage – Lead acid battery
13.0 – 13.8V
IP class
IP22
OPERATING INSTRUCTIONS
STEP 1 - Pre-Charge Check & Electrolyte Level Check
•
Check the Battery Electrolyte level for Lead Acid battery (not required on sealed & maintenance free batteries). If necessary,
remove the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines.
STEP 2 - Connecting the Battery Charger to your Battery
•
Connect the Red lead from the charger to the positive (+) battery terminal.
•
Connect the Black lead from the charger to the negative (-) battery terminal.
Summary of Contents for 700546
Page 27: ...www bs battery com...