21
3.000V
0.9% + 2d
Test Current: 0.3mA typical
Open Circuit Voltage: < 3.2VDC typical
200.0 A, 2000 A
0.7% + 3d
2.5mV/ A
200.0 A, 2000 A
1.0% + 3d
2.5mV/ A
1)
Combination PTC protective impedance is being used
6.000A, 10.00A
1)
0.7% + 3d
0.04V/A
6.000A
2)
, 10.00A
1)
1.0% + 3d
0.04V/A
1)
10A continuous, >10A to 20A for 30 seconds max with 5 minutes cool down interval
2)
<5d nonzero residue may appear when backlight is on, which will not affectthe
specified measuring range and accuracy
40.0
o
C ~ 99.9
o
C
1% + 1
o
C
100
o
C ~ 400
o
C
40.0
o
F ~ 99.9
o
F
1% + 2
o
F
100
o
F ~ 752
o
F
Accuracies assume meter interior and the ambient have reached the same temperature
(isothermal stage) for a correct junction voltage compensation. Allow enoughsettling time for
a significant change of ambient temperature. It can take up to an hour for changes > 5°C.
2)
TypeK thermocouple range & accuracy not included