For most autoranging functions (LCD
turns on by default), press the
button momentarily to select manual ranging override. The meter will remain in the
range it was in, the LCD
turns off. Press the button momentarily aga in to select
the next range. Press and hold the button for 1 se
cond or more to resume auto
ranging.
Note: Manualranging feature is not availableto AutoV, Capacitance & Hz functions.
to the meter due to improper connections to the A, mA, or A input jacks whenanother
function, especially avoltage function, is selected.
The AutoPoweroff (APO) mode turns the meter off automatically to extend battery life
after approximately32 minutes of no specified activities, where applicable:
1) Rotary switch or push button operations
2) Significant measuring readings of above8.5% of ranges
3) NonOL readings for Resistance, Continuity or Diode function
4) Nonzero readings for Hz function
5) Electric field signal present for EF function
6) Significant movement indication as in Phase Rotation functions
In other words, the meter will intelligently avoid entering the APO mode when it is
under normal measurements. To wake up the meter from APO, press the
button momentarily and release, or turn the rotary switch OFF and then back on.
Always turn therotary switch to the OFF position when the meter is not in use
To avoid electrical shock, disconnect the meter from any circuit, remove the test leads
from the input jacks and turn OFF the meter before opening the case. Do not operate
with open case. Install only the same type of fuse(s) or equivalent
Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives
or solvents. If the meter is not to be used for periods of longer than 60 days, r
emove
the battery and store it separately