—30—
HEAT PUMP HEATING PERFORMANCE Continued
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
EDB
CFM
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW†
650A042-D, E Outdoor Section With FV4(A,B)NF003 Indoor Section
65
1225
17.3 15.9 2.61 21.5 19.7 2.74 25.6 23.4 2.86 30.0 26.6 2.99 35.1 32.0 3.15 41.1 41.1 3.35 48.2 48.2 3.61 56.4 56.4 3.96
1400
17.6 16.1 2.61 21.7 20.0 2.73 25.9 23.6 2.84 30.2 26.9 2.95 35.5 32.3 3.09 41.6 41.6 3.28 48.8 48.8 3.53 57.2 57.2 3.86
1575
17.8 16.4 2.62 21.9 20.2 2.73 26.1 23.8 2.83 30.5 27.1 2.93 35.8 32.6 3.06 42.0 42.0 3.24 49.4 49.4 3.47 57.1 57.1 3.72
70
1225
16.8 15.4 2.74 21.1 19.4 2.88 25.4 23.1 3.03 29.6 26.3 3.16 34.7 31.6 3.33 40.5 40.5 3.53 47.5 47.5 3.81 55.5 55.5 4.17
1400
17.1 15.7 2.74 21.3 19.6 2.87 25.6 23.3 3.00 29.9 26.6 3.12 35.0 31.9 3.27 41.0 41.0 3.46 48.1 48.1 3.72 56.3 56.3 4.06
1575
17.3 15.9 2.75 21.6 19.8 2.87 25.8 23.5 2.99 30.2 26.8 3.10 35.3 32.2 3.24 41.4 41.4 3.41 48.6 48.6 3.66 56.9 56.9 4.00
75
1225
16.2 14.9 2.88 20.6 18.9 3.03 25.1 22.8 3.19 29.3 26.0 3.34 34.3 31.2 3.51 39.9 39.9 3.73 46.7 46.7 4.01 54.6 54.6 4.39
1400
16.5 15.2 2.88 20.9 19.2 3.02 25.3 23.1 3.17 29.6 26.3 3.30 34.6 31.5 3.46 40.4 40.4 3.65 47.3 47.3 3.91 55.4 55.4 4.27
1575
16.7 15.4 2.89 21.1 19.4 3.02 25.5 23.3 3.15 29.8 26.5 3.27 34.9 31.7 3.42 40.8 40.8 3.60 47.8 47.8 3.85 56.0 56.0 4.20
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AC
048
0.99
1.10
CC5A/CD5AC
048
0.99
1.08
CC5A/CD5AW
048
1.00
1.05
CC5A/CD5AW
048
1.00
1.04
CD5AA
048
1.00
1.05
CD5AA
048
1.00
1.03
CK5A/CK5BA
048
1.00
1.01
CK3BA
048
1.00
1.00
CK5A/CK5BT
048
1.00
1.01
CK5A/CK5BA
048
1.00
1.00
CK5PA
048
1.00
1.01
CK5A/CK5BT
048
1.00
1.00
CK5PT
048
1.00
1.01
CK5A/CK5BW
048
1.00
1.01
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CK5PA
048
1.00
1.00
CC5A/CD5AC
048
0.99
1.08
CK5PT
048
1.00
1.00
CC5A/CD5AW
048
1.00
1.04
CK5PW
048
1.00
1.01
CD5AA
048
1.00
1.04
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CK3BA
048
1.00
1.01
CC5A/CD5AC
048
0.99
1.08
CK5A/CK5BA
048
1.00
1.01
CC5A/CD5AW
048
1.00
1.04
CK5A/CK5BT
048
1.00
1.01
CD5AA
048
1.00
1.04
CK5PA
048
1.00
1.01
CK5A/CK5BW
048
1.00
1.00
CK5PT
048
1.00
1.01
CK5PW
048
1.00
1.00
See notes on page 32.