2

PERSONAL INJURY AND EQUIPMENT DAMAGE

HAZARD

Failure to follow this caution may result in personal injury

and / or equipment damage.

DO NOT

operate the unit without a filter or with grille

removed.

CAUTION

!

Step 1

Complete Pre--Installation Checks

Unpack Unit

Move the unit to final location. Remove unit from carton, being

careful not to damage service valves and grilles.

Inspect Shipment

File a claim with the shipping company if shipment is damaged or
incomplete. Check the unit nameplates to ensure units match job

requirements.

Consider System Requirements

Consult local building codes and NEC for special installation
requirements.
Allow sufficient space for airflow clearance, wiring, refrigerant
piping, and servicing unit. Locate unit so that condenser airflow is

unrestricted on both sides.
Unit may be mounted on a level pad directly on base legs or
mounted on raised pads at support points.

Matching the Condensing Unit to an Indoor Unit

The 538A018--060 condensing units can be matched to

corresponding indoor units. The 538A unit can be matched with
under--ceiling duct--free and residential ducted fan coils and

evaporator coils. Refer to separate indoor unit literature for more

information.

Step 2

RIG AND MOUNT UNIT

Mounting on Ground

Mount unit on a solid, level concrete pad. Position unit so water or
ice from roof does not fall directly onto unit. Accessory stacking

kits can be used when units are to be stacked. See installation

instructions provided with the accessory kit. Use field--provided
snow stand or ice rack where prolonged subfreezing temperatures

or heavy snow occurs.
If conditions or local codes require unit be fastened to a pad, 6

field--supplied tie--down bolts should be used and fastened through
slots provided in unit mounting feet.

Mounting on Roof

Mount unit on a level platform or frame at least 6 in. (152.4 mm)

above roof surface. Isolate unit and tubing from structure.

Clearance Requirements

With coil facing wall: Allow 6” (152.4 mm) minimum clearance

on coil side and coil end and 36” (914.4 mm) minimum clearance
on compressor end and fan side
With fan facing wall: Allow 8” (203.2 mm) minimum clearance on
fan side and coil end and 36” (914.4 mm) minimum clearance on

compressor end and coil side.
With multi--unit application: Arrange units so discharge of one

does not enter inlet of another.

IMPORTANT

: When installing multiple units, ensure the

discharge air from one unit is not drawn into another unit. When
installing single or multiple units in an alcove, roof well or partially
enclosed area, ensure there is adequate ventilation to prevent
recirculation of discharge air.

Operating Ambient

Minimum outdoor operating ambient in cooling mode without
accessory is 55

_

F (13

_

C), maximum 125

_

F (52

_

C).

Rigging

PERSONAL INJURY AND/OR EQUIPMENT DAMAGE

HAZARD

Failure to follow this caution may result in personal injury

and/or equipment damage.
Be sure unit panels are securely in place prior to rigging.

CAUTION

!

Keep the unit upright and lift unit using a sling. Use cardboard or
padding under the sling, and spreader bars to prevent sling damage

to the unit. See Fig. 2. Install the unit so that the coil does not face

into prevailing winds. If this is not possible and constant winds
above 25 mph are expected, use accessory wind baffle. See

installation instructions provided with the accessory kit.

NOTE

: Accessory wind baffles should be used on all units with

accessory low ambient temperature control.
Field--fabricated snow or ice stands may be used to raise unit when

operation will be required during winter months. Units may also be
wall mounted using the accessory wall mounting kit.

A07396

Fig. 2

---

Lifting Unit with Sling

Step 3

COMPLETE REFRIGERANT PIPING CONNEC-

TIONS

Outdoor units may be connected to indoor units using

field--supplied tubing of refrigerant grade and condition. See
Product Data for correct line sizes. Do not use less than 10 ft (3.1

m) of interconnecting tubing.

CAUTION

!

UNIT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage

or improper operation.
If any section of pipe is buried, there must be a 6 in. (152.4

mm) vertical rise to the valve connections on the outdoor unit.

If more than the recommended length is buried, refrigerant

may migrate to cooler, buried section during extended periods

of system shutdown. This causes refrigerant slugging and

could possibly damage the compressor at start--up.

When more than 80 ft (24.38 m) of interconnecting tubing and

more than 20 ft (6.10 m) of vertical lift is used, consult the
residential Long Line Application Guide for required accessories.

If either refrigerant tubing or indoor coil is exposed to the

atmosphere, the system must be evacuated following good
refrigeration practices.
Run refrigerant tubes as directly as possible, avoiding unnecessary
turns and bends. Suspend refrigerant tubes so they do not damage

insulation on vapor tube and do not transmit vibration to structure.
Also, when passing refrigerant tubes through a wall, seal the

opening so that vibration is not transmitted to structure. Leave

538A