COIL STATIC PRESSURE DROP (In. WC)

INDOOR COIL PISTONS

 

UNIT SIZE

BULB

AIR QUANTITY (CFM)

 

A018

 

400

500

600

700

800

 

WET

0.08

0.12

0.16

0.22

0.29

DRY

0.07

0.11

0.15

0.20

0.27

A024

 

600

700

800

900

 

WET

0.16

0.21

0.26

0.31

DRY

0.14

0.19

0.24

0.29

W024

 

600

700

800

900

 

WET

0.15

0.20

0.24

0.30

DRY

0.13

0.18

0.23

0.29

A030

 

700

800

900

1000

1100

 

WET

0.17

0.22

0.28

0.33

0.41

DRY

0.16

0.21

0.27

0.32

0.40

W030

 

700

800

900

1000

1100

 

WET

0.13

0.16

0.20

0.24

0.27

DRY

0.10

0.14

0.17

0.20

0.24

A036
T036

 

900

1000

1100

1200

1300

 

WET

0.18

0.22

0.26

0.30

0.35

DRY

0.15

0.18

0.22

0.26

0.30

W036

 

900

1000

1100

1200

1300

 

WET

0.15

0.18

0.21

0.25

0.28

DRY

0.12

0.14

0.16

0.19

0.23

N036

 

800

900

1000

1100

 

WET

0.24

0.29

0.36

0.44

DRY

0.23

0.28

0.34

0.43

A042
T042

 

1000

1100

1200

1300

1400

 

WET

0.18

0.21

0.25

0.28

0.32

DRY

0.14

0.16

0.19

0.23

0.24

N042

 

1000

1100

1200

1300

1400

 

WET

0.22

0.26

0.30

0.35

0.41

DRY

0.18

0.22

0.26

0.30

0.34

A048
T048

 

1300

1400

1500

1600

 

WET

0.21

0.24

0.28

0.31

DRY

0.19

0.22

0.25

0.28

W048

 

1300

1400

1500

1600

1700

 

WET

0.16

0.17

0.19

0.21

0.23

DRY

0.14

0.16

0.18

0.20

0.22

N048

 

1200

1300

1400

1500

 

WET

0.25

0.30

0.34

0.40

DRY

0.23

0.27

0.31

0.35

N060

 

1600

1700

1800

 

WET

0.27

0.30

0.33

DRY

0.25

0.28

0.31

A060
T060

 

1600

1700

1800

1900

2000

2100

 

WET

0.19

0.21

0.23

0.26

0.29

0.33

DRY

0.17

0.19

0.21

0.23

0.25

0.28

X060

 

1600

1700

1800

1900

2000

2100

 

WET

0.21

0.23

0.25

0.27

0.29

0.31

DRY

0.16

0.18

0.20

0.22

0.25

0.27

 

UNIT

FACTORY-INSTALLED

INDOOR PISTON SIZE

 

CK5A/CK5BA018

52

CK5A/CK5BA024, W024

59

CK5A/CK5BA030, W030

67

CK5A/CK5BA036, N036, T036, W036

70

CK5A/CK5BA042, N042, T042

78

CK5A/CK5BA048, N048, T048, W048

84

CK5A/CK5BA060, N060, T060, X060

90

Summary of Contents for CK5A

Page 1: ...ith a slope to help ensure proper drainage im proved moisture removal and home comfort Compact Design Unique design offers as much as 2 in less in height to aid in tight installations Brass Inserts Ev...

Page 2: ...c 014 14 3 16 in 017 17 1 2 in 021 21 in 024 24 1 2 in A Standard N Narrow T Transition W Wide X Max Cap Position A Painted B Embossed M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I...

Page 3: ...B XW036021 B 21 17 5 8 19 3 8 10 1 2 3 4 2 1 8 1 3 8 44 CK5 A B XA042021 B 21 17 5 8 19 3 8 10 1 2 7 8 2 1 8 1 3 8 44 CK5 A B XN042017 B 17 1 2 17 5 8 15 7 8 10 7 8 7 8 2 1 8 1 3 8 43 CK5 A B XT042021...

Page 4: ...1 0 26 1250 72 72 1 33 0 0 00 64 7 29 9 0 00 57 3 26 8 0 20 49 4 23 7 0 15 40 1 20 3 0 14 67 59 6 35 8 0 14 52 4 32 7 0 14 45 3 29 5 0 13 36 8 25 9 0 13 27 5 22 0 0 15 62 49 0 38 4 0 14 42 0 35 2 0 13...

Page 5: ...0 13 51 1 51 1 0 18 42 5 42 5 0 32 X060 1600 72 106 0 49 0 0 00 94 4 44 0 0 00 83 1 39 0 0 07 71 6 34 3 0 05 58 4 29 1 0 06 67 85 7 51 3 0 05 75 4 46 5 0 05 65 1 41 7 0 05 52 9 36 4 0 05 39 8 30 9 0 0...

Page 6: ...4 0 43 A042 T042 1000 1100 1200 1300 1400 WET 0 18 0 21 0 25 0 28 0 32 DRY 0 14 0 16 0 19 0 23 0 24 N042 1000 1100 1200 1300 1400 WET 0 22 0 26 0 30 0 35 0 41 DRY 0 18 0 22 0 26 0 30 0 34 A048 T048 13...

Page 7: ...7...

Page 8: ...this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats...

Reviews: