—24—

TYPICAL WIRING SCHEMATIC — 230-1-60 SHOWN

Summary of Contents for 604B

Page 1: ...contamination to help promote longer life and dependable operation Vibration isolation pro vides quiet operation Compressors have internal high pressure and overcurrent protection Convertible duct con...

Page 2: ...from being affected by the outdoor ambient temperature and provides improved indoor air quality Conforms to American Society of Heating Refriger ation and Air Conditioning Engineers No 62P The sloped...

Page 3: ...TY BTUH 47 F HIGH HEAT COP 47 F LOW HEAT CAPACITY BTUH 17 F LOW HEAT COP 17 F HSPF 024 24 000 3 4 14 400 2 2 7 8 030 29 000 3 4 16 000 2 2 8 0 036 36 000 3 4 19 600 2 1 8 0 042 40 500 3 4 21 600 2 2 8...

Page 4: ...8 825 2700 22 1 8 825 2800 22 1 8 825 2800 22 1 8 825 3300 22 1 4 1100 3300 22 1 4 1100 INDOOR COIL Rows Fins in Face Area sq ft 3 15 3 7 3 15 3 7 4 15 3 7 3 15 4 7 4 15 4 7 4 15 5 7 STANDARD INDOOR...

Page 5: ...ts that are used to assist in lift ing this product onto a roof application Crankcase heater provides anti floodback protection for low load cooling applications Low ambient kit Motormaster II control...

Page 6: ...6 ECONOMIZER FILTER RACK MANUAL OUTSIDE AIR DAMPER DAMPER BLADE MANUAL OUTSIDE AIR HOOD REPLACEMENT PANEL...

Page 7: ...HEIGHT in mm A CENTER OF GRAVITY in mm lb kg X Y Z 604B024 208 230 1 60 350 159 37 02 940 3 20 0 508 0 19 3 489 0 17 6 447 0 604B030 208 230 1 60 350 159 39 02 991 1 20 0 508 0 19 3 489 0 17 6 447 0 6...

Page 8: ...CENTER OF GRAVITY in mm lb kg X Y Z 604B042 208 230 1 60 208 230 3 60 440 200 42 98 1091 7 21 533 4 20 5 520 7 16 6 421 6 604B048 208 230 1 60 208 230 3 60 463 210 44 98 1142 5 19 5 495 3 17 6 447 6...

Page 9: ...ng B x C Long Support D 44 5 16 1125 5mm Return opening B X C Insulated deck pan Short Support C Typ UNIT SIZE ODS ORDER NO A in mm B in mm C in mm D in mm ROOF CURB 024 036 CPRFCURB006A00 8 203 11 27...

Page 10: ...ric Heater table on page 5 for 208 230 v single phase unit The 5 kW heater at 240v most closely satisfies the heating required To calculate kw at 230v multiply the heater kw by multiplication factor 0...

Page 11: ...Outdoor Coil F db at 70 rh 10 0 10 17 20 60 800 TC 7 05 6 52 9 38 8 63 11 68 10 72 27 90 25 44 14 58 13 22 kW 1 49 1 56 1 63 1 69 1 71 900 TC 7 27 6 73 9 55 8 79 11 92 10 94 13 67 12 46 14 81 13 43 kW...

Page 12: ...3 2 3 2 3 2 604B030 Return Air F db CFM Standard Air Air Temperature Entering Outdoor Coil F db at 70 rh 10 0 10 17 20 60 875 TC 9 4 8 7 11 9 10 9 14 4 13 2 16 3 14 9 17 2 15 6 kW 1 74 1 81 1 89 1 97...

Page 13: ...5 604B036 Return Air F db CFM Standard Air Air Temperature Entering Outdoor Coil F db at 70 rh 10 0 10 17 20 60 1100 TC 12 1 11 2 15 1 13 9 18 5 16 9 21 4 19 5 22 8 20 7 kW 2 25 2 34 2 43 2 49 2 51 1...

Page 14: ...604B042 Return Air F db CFM Standard Air Air Temperature Entering Outdoor Coil F db at 70 rh 10 0 10 17 20 60 1225 TC 13 6 12 5 16 6 15 3 19 7 18 1 22 2 20 2 23 7 21 5 kW 2 42 2 51 2 64 2 76 2 81 140...

Page 15: ...0 60 1400 TC 15 10 14 00 18 60 17 10 22 40 20 50 25 20 23 00 26 90 24 40 kW 2 66 2 76 2 87 2 95 3 00 1600 TC 15 40 14 30 18 90 17 40 22 70 20 90 25 60 23 30 27 30 24 80 kW 2 70 2 79 2 89 2 96 3 03 180...

Page 16: ...0 rh 10 0 10 17 20 60 1500 TC 17 89 16 55 22 37 20 58 27 39 25 14 27 90 25 44 33 30 30 20 kW 3 14 3 33 3 56 3 71 3 76 1750 TC 18 44 17 06 22 91 21 08 28 07 25 77 32 32 29 47 34 25 31 06 kW 3 23 3 39 3...

Page 17: ...and the heat required to defrost it NOTES 1 Ratings are net they account for the effects of the evaporator fan motor power and heat 2 Direct interpolation is permissible Do not extrapolate 3 The foll...

Page 18: ...NG 1110 1025 970 1235 1175 1115 1400 1355 1280 COOLING DEHUMIDIFY 990 960 910 990 975 940 1125 1110 1085 HEAT PUMP COMFORT 1035 975 910 1160 1080 1020 1305 1275 1220 UNIT SIZE CFM ADJUST PIN SELECT LO...

Page 19: ...800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 024 030 20 X 20 X 1 0 05 0 07 0 08 0 10 0 12 0 13 0 14 0 15 36 20 X 24 X 1 0 09 0 10 0 11 0 13 0 14 0 15 0 16 042 048 060...

Page 20: ...R NEC FROM POWER SOURCE RETURN AIR TOP COVER NEC NATIONAL ELECTRICAL CODE TYPICAL PIPING AND WIRING ROOF RETURN AIR FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX FIELD SUPPLIED SUPPLY AIR FLEXIBLE DUC...

Page 21: ...evaporator airflow through the units should not exceed 450 cfm ton Minimum cooling airflow The minimum airflow is 350 cfm ton for cooling mode Airflow can be lower in certain modes when humidity remov...

Page 22: ...20 8 26 30 36 1 41 7 54 2 62 5 72 2 83 3 35 7 35 7 58 3 61 7 68 2 73 2 80 8 87 8 103 4 113 8 126 0 139 9 45 45 80 80 90 90 100 100 125 125 150 150 208 230 3 60 187 253 15 4 88 0 0 9 6 8 3 8 5 0 7 5 1...

Page 23: ...where a phase imbalance in supply volt age is greater than 2 Use the following formula to determine the percentage of voltage imbalance Voltage imbalance max voltage deviation from average voltage 10...

Page 24: ...24 TYPICAL WIRING SCHEMATIC 230 1 60 SHOWN...

Page 25: ...25 TYPICAL WIRING SCHEMATIC 208 230 3 60 SHOWN 1 3 2...

Page 26: ...c heat When thermostat is satisfied contacts open deenergizing contactor and relay motors and heaters deenergize The IFM is controlled by the Easy Select board Defrost Defrost board DB is a time and t...

Page 27: ...ction 5 Unit shall have a field supplied condensate trap C Fans 1 The indoor fan shall be variable speed motor and con trol as shown on equipment drawings 2 Fan wheel shall be made from steel and shal...

Page 28: ...h can be preset to admit outdoor air for year round ventilation 5 Thermostat To provide for two stage heating and one stage cooling in addition manual or automatic changeover and indoor fan control 6...