PERFORMANCE DATA–STANDARD ECM INDOOR MOTOR
COOLING EXTENDED PERFORMANCE TABLE
HEATING EXTENDED PERFORMANCE TABLE
-10–20
HEATING EXTENDED PERFORMANCE TABLE
30–60
*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 17.
604B024 COOLING PERFORMANCE TABLE
Temp (F)
Outdoor Air
Entering
Condenser
Evaporator Air—CFM/BF
800/0.026
900/0.032
1000/0.04
Evaporator Air — Ewb (F)
62
63*
67
72
62
63*
67
72
62
63*
67
72
75
TC
24.0
24.5
26.5
29.1
24.6
25.1
27.1
29.8
25.1
25.5
27.4
30.4
SHC
21.9
21.3
18.7
15.4
23.5
22.8
19.8
16.1
25.0
24.2
20.8
16.7
kW
1.7
1.7
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
85
TC
22.9
23.3
25.3
27.9
23.5
23.9
25.8
28.5
23.9
24.3
26.2
28.9
SHC
21.4
20.7
18.1
14.9
22.9
22.2
19.2
15.6
24.3
23.6
20.3
16.2
kW
1.9
1.9
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.1
2.1
95
TC
21.8
22.2
24.0
26.5
22.3
22.6
24.5
27.0
22.7
23.0
24.8
27.4
SHC
20.8
20.2
17.6
14.3
22.3
21.6
18.7
15.0
23.6
22.9
19.7
15.6
kW
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.3
2.3
105
TC
20.5
20.9
22.6
25.0
21.0
21.3
23.0
25.4
21.6
21.7
23.3
25.7
SHC
20.2
19.5
16.9
13.7
21.6
20.9
18.0
14.3
22.5
22.2
19.0
14.9
kW
2.4
2.4
2.4
2.4
2.4
2.4
2.5
2.5
2.5
2.5
2.5
2.5
115
TC
19.2
19.5
21.1
23.3
19.8
19.9
21.5
23.7
20.7
20.4
21.7
23.6
SHC
19.4
18.8
16.3
13.0
20.6
20.2
17.3
13.7
21.5
21.2
18.3
14.1
kW
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.8
2.8
125
TC
17.8
18.0
19.4
21.4
18.5
18.5
19.5
21.7
19.0
19.0
19.9
21.9
SHC
18.5
18.1
15.5
12.3
19.2
19.2
16.5
12.9
19.8
19.7
17.6
13.5
kW
2.9
2.9
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.1
3.1
604B024
Return
Air (F db)
CFM (Standard Air)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
-10
0
10
17
20
60
800
TC
7.05
6.52
9.38
8.63
11.68
10.72
27.90
25.44
14.58
13.22
kW
1.49
1.56
1.63
1.69
1.71
900
TC
7.27
6.73
9.55
8.79
11.92
10.94
13.67
12.46
14.81
13.43
kW
1.51
1.57
1.64
1.69
1.70
1000
TC
7.44
6.88
9.74
8.96
12.11
11.11
13.90
12.67
15.02
13.62
kW
1.53
1.59
1.65
1.70
1.70
70
800
TC
6.20
5.73
8.57
7.89
11.05
10.15
12.80
11.67
13.93
12.63
kW
1.63
1.71
1.80
1.86
1.88
900
TC
6.37
5.89
8.78
8.08
11.24
10.32
13.07
11.91
14.19
12.86
kW
1.65
1.72
1.80
1.86
1.88
1000
TC
6.56
6.07
8.98
8.26
11.49
10.55
13.28
12.10
14.43
13.08
kW
1.68
1.75
1.82
1.87
1.89
80
800
TC
5.19
4.80
7.66
7.05
10.24
9.40
12.05
10.99
13.23
12.00
kW
1.77
1.87
1.97
2.04
2.06
900
TC
5.35
4.95
7.85
7.23
10.47
9.61
12.31
11.23
13.49
12.23
kW
1.79
1.88
1.98
2.04
2.06
1000
TC
5.53
5.12
8.06
7.41
10.70
9.82
12.55
11.44
13.71
12.44
kW
1.83
1.91
2.00
2.05
2.07
604B024
Return
Air (F db)
CFM (Standard Air)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
30
40
47
50
60
60
800
TC
18.93
16.58
22.27
22.27
23.82
23.82
23.82
23.82
25.12
25.12
kW
1.77
1.80
1.79
1.79
1.81
900
TC
19.10
16.74
22.23
22.23
23.74
23.74
24.09
24.09
24.29
24.29
kW
1.75
1.77
1.76
1.77
1.76
1000
TC
19.27
16.89
21.64
21.64
23.46
23.46
23.61
23.61
23.83
23.83
kW
1.75
1.75
1.75
1.75
1.75
70
800
TC
18.39
16.11
22.24
22.24
23.80
23.80
23.94
23.94
24.42
24.42
kW
1.95
1.99
1.99
1.99
1.99
900
TC
18.69
16.38
22.08
22.08
27.70
27.70
23.67
23.67
24.20
24.20
kW
1.93
1.97
2.09
1.96
1.96
1000
TC
18.86
16.53
21.85
21.85
23.43
23.43
23.40
23.40
24.27
24.27
kW
1.94
1.95
1.94
1.94
1.95
80
800
TC
17.52
15.35
22.02
22.02
23.88
23.88
23.98
23.98
24.58
24.58
kW
2.14
2.20
2.21
2.21
2.22
900
TC
17.79
15.59
22.09
22.09
23.62
23.62
23.81
23.81
24.34
24.34
kW
2.11
2.17
2.17
2.17
2.18
1000
TC
18.17
15.92
21.92
21.92
23.55
23.55
23.73
23.73
24.38
24.38
kW
2.11
2.17
2.16
2.16
2.16