PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in increase furnace

operating temperatures and shorten the life of the furnace.
Filters specified for the furnace are rated at a maximum of 600

FPM air velocity and sized for the furnace’s airflow rate.

Replacement filters must be of equivalent type, size, and rating

except as described below.
Disposable, low--velocity filters may be used to replace

washable, high--velocity filters, providing they are sized for

300 FPM or less.
If you are uncertain of the type of replacement filter to use,

consult the furnace installer or a qualified service agency for

assistance.

CAUTION

!

Filter Replacement -- Bottom or Side Mounted

Filter Rack Outside Furnace

1. Turn OFF electric power to furnace.
2. Remove the end cap from the filter rack.
3. Slide the filter out of the filter rack. See Fig. 4.
4. Inspect the filter(s) and replace or clean washable types. If

filter is aluminum mesh it should be recoated with filter
coating spray.

Filter Rack End Cap

A07690

Fig. 4 -- Filter Rack Outside Furnace

5. Reinstall the end cap in the filter rack.
6. Turn on electric power to furnace.

Filter Replacement -- Bottom Mounted Filter

Inside Furnace

1. Turn off electric power to furnace.
2. Remove blower door.
3. Slide filter straight out toward you. See Fig. 5.
4. Inspect the filter(s) and replace or clean washable types. If

filter is aluminum mesh it should be recoated with filter

coating spray.

5. Replace blower door.
6. Turn on electric power to furnace.

9

Center Clip

side--to--side

(228.6 mm)

A07691

Fig. 5 -- Bottom Mounted Filter Inside Furnace

External Filter Rack

A plastic end cap is inserted in the filter rack after the filter is
installed. The end cap keeps air from escaping around the open end

of the filter rack. See Fig. 4 for removal of filter.
Filter racks attached to the furnace are made so the filter simply

slides out one end for removal.

1. Turn OFF electric power to furnace.
2. Remove the end cap from the filter rack.
3. Slide the filter out of the filter rack.
4. Inspect the filter(s) and replace or clean washable types. If

filter is aluminum mesh it should be recoated with filter

coating spray.

5. Reinstall the end cap in the filter rack.
6. Turn furnace on.

Internally Mounted Filter

1. Turn OFF power to furnace.
2. Remove blower door.
3. Slide filter straight out toward you. (See Fig. 5.)
4. Inspect the filter(s) and replace or clean washable types. If

filter is aluminum mesh it should be recoated with filter

coating spray.

5. Replace blower door.
6. Turn on electric power to furnace.

Lubrication

The blower motor and the combustion air blower are

pre--lubricated by the manufacturer and DO NOT require oiling.

Qualified Service Agency Checks

When the furnace is being inspected for condition and operation

have the Qualified Service Agency check the following items.

1. Check all flue gas passages including main and pilot burn-

ers, heat exchanger, and vent.

2. Check electrical wiring and connections.
3. Check supply and return air ducts for leakage, blockage and

connections to furnace.

4. Check circulating air blower wheel and motor. Clean them

if required.

5. Perform an operational checkout on the furnace to be sure

safety controls function and that furnace operates properly.

For additional information, the Qualified Service Agency can

consult the installation instructions for the furnace.

359B

A

V

Summary of Contents for 359BAV

Page 1: ...ice agency should be contacted to inspect the furnace and to replace all gas controls control system parts electrical parts that have been wet or the furnace if deemed necessary CERTIFIED As an ENERGY...

Page 2: ...ze 5 On appliances with a draft hood check for spillage by hold ing a lighted match 2 50 8mm from the draft hood open ing Reference Fig 1 which shows a water heater draft hood Typical Gas Water Heater...

Page 3: ...have a Fan Switch with AUTO and ON settings On AUTO the Circulating Air Blower will cycle on off with the furnace on the heating speed unless a call for cooling is initiated Blower speed will correspo...

Page 4: ...ors 8 Turn ON all electrical power to the furnace 9 Set the thermostat to the desired temperature and the System Select Switch to HEAT The furnace will activate an igniter which lights the main burner...

Page 5: ...cleaned or replaced as required There are many types of filters that are commonly used Washable filters constructed of aluminum mesh foam or reinforced fibers may be cleaned by soaking in mild deterge...

Page 6: ...ace External Filter Rack A plastic end cap is inserted in the filter rack after the filter is installed The end cap keeps air from escaping around the open end of the filter rack See Fig 4 for removal...

Page 7: ...rs 800 900 20 x 25 508 x 635 1 Req 14 x 25 356 x 635 1 Req 1100 1300 14 x 25 356 x 635 2 Req 14 x 25 356 x 635 1 Req 1300 1500 16 x 18 406 x 457 2 Req 16 x 18 406 x 457 1 Req 1500 1700 20 x 25 508 x 6...

Page 8: ...Systems TO OBTAIN INFORMATION ON PARTS Consult your installing dealer or classified section of your local telephone directory under the Heating Equipment or Air Conditioning Contractors Systems headin...

Reviews: