background image

4

BRYANT ACCESSORIES

DESCRIPTION 313AAV/JAV

PART NO.

024045

048070

048090

060110

060135

Cartridge Media Filter

FILBBCAR0016

X

X

FILBBCAR0020

X

X

FILBBCAR0024

X

EXPXXUNV0016

X

X

EZ Flex Media Filter with End Caps

EXPXXUNV0020

X

X

EXPXXUNV0024

X

EXPXXFIL0016

X

X

Replacement EZ Flex Filter Media

EXPXXFIL0020

X

X

EXPXXFIL0024

X

External Bottom Return

KGAFR0401B14

X

KGAFR0501B17

X

Filter Rack

KGAFR0601B21

X

X

KGAFR0701B24

X

External Side Return Filter Rack

KGAFR0801SRE

X

X

X

X

X

Unframed Filter 1 in. (25mm)

KGAWF1306UFR

X

X

S

{

S

{

S

{

KGAWF1406UFR

X

X

KGAWF1506UFR

X

Flue Extension

KGAFE0112UPH

X

X

X

X

X

Combustible Floor Base

KGASB0201ALL

X

X

X

X

X

Downflow Vent Guard

KGAVG0101DFG

X

X

X

X

X

Vent Extension Kit

KGAVE0101DNH

X

X

X

X

X

Chimney Adapter Kit

KGACA02014FC

X

X

X

X

Chimney Adapter Kit

KGACA02015FC

X

Natural---to---Propane Conversion Kit*

KGANP4601ALL

X

X

X

X

X

Propane---to---Natural Conversion Kit*

KGAPN3901ALL

X

X

X

X

X

Label Kit

KGALB0101KIT

X

X

X

X

X

Air Leakage Kit (Qty 10)

KGBAC0110DGK

X

X

X

X

X

Gas Orifice Kit (Qty 50)

KGAHA0150N42

See Installation Instructions for model, altitude, and heat value usages.

KGAHA0250N43

(factory supplied)
KGAHA0350N44
KGAHA0450N45
KGAHA0550N46
KGAHA1550N47
KGAHA1650N48
KGAHA0650P54
KGAHA0750P55

*Factory---authorized and field---installed. Gas conversion kits are CSA (AGA/CGA) recognized.

{

Suitable for side return.

X Available accessory

313AA

V/

JA

V

Summary of Contents for 313AAV PLUS 80X

Page 1: ...onditioning Heating and Refrigeration Institute s standard coil only ratings when paired with selected Bryant evaporator coils STANDARD FEATURES S ECM blower motor included S Noise elimination combust...

Page 2: ...UAL RESET LIMIT SWITCHES GAS VALVE FLUE COLLECTOR BOX PRESSURE SWITCH INDUCER MOTOR ASSEMBLY CAPACITOR POWER CHOKE WHERE USED A02259 NOTE The 313AAV JAV Furnaces are factory shipped for use with natur...

Page 3: ...1 speed Air Conditioner deg F C Auto Changeover T6 NAC T2 NAC For use with 1 speed Air Conditioner deg F C Auto Changeover T6 NHP T2 NHP For use with 2 speed Air Conditioner deg F C Auto Changeover T6...

Page 4: ...PH X X X X X Combustible Floor Base KGASB0201ALL X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X Vent Extension Kit KGAVE0101DNH X X X X X Chimney Adapter Kit KGACA02014FC X X X X Chimney Adapter...

Page 5: ...Gas Maximum Inlet Pressure in wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft 610 M For elevations above 2000 ft 610 M reduce ratings 4 percen...

Page 6: ...lations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in single wall vent must be us...

Page 7: ...9 SEE NOTES 1 2 4 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL LEFT HORIZONTAL LEFT HORIZONTAL LEFT HORIZ...

Page 8: ...40 1065 1005 925 865 790 1 1280 1205 1140 1055 990 910 840 760 695 630 060135 Bottom or Side s 5 2295 2240 2185 2125 2070 2005 1925 1805 1670 1545 4 1725 1660 1605 1545 1460 1395 1340 1285 1230 1170 3...

Page 9: ...4 1 2 x 12 in 368 x 305 mm rectangle b For 1200 CFM 20 in 508 mm round or 14 1 2 x 19 1 3 in 368 x 491 mm rectangle c For 1600 CFM 22 in 559 mm round or 14 1 2 x 22 1 16 in 368 x 560 mm rectangle d Fo...

Page 10: ...in the horizontal position Line contact only permissible between lines formed by intersections of the Top and two Sides of the furnace jacket and building joists studs or framing DOWNFLOW POSITIONS D...

Page 11: ...V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES Connect Y terminal in furnace as shown for proper blower operation Some therm...

Page 12: ...________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard...

Reviews: