Bryant 313AAV PLUS 80X Product Data Download Page 3

3

BRYANT ACCESSORIES

MECHANICAL

OR ELECTRONIC

AIR CLEANER

Cleans the air of smoke, dirt, and 
many pollens commonly found. 
Saves decorating and cleaning 
expenses by keeping carpets, 
furniture, and drapes cleaner.

Electronic air cleaner is shown.

A97432

CONTROLS:

THERMOSTATS

AND ZONING

Available in programmable and 
non-programmable models, 

Bryant thermostats maintain a 

constant, comfortable tempera-
ture level in the home.

For the ultimate in home comfort, 

Bryant’s 2, 4, and 8-zone systems 

allow temperature control of indi-
vidual “zones” of the home. This is 
accomplished through a series of 
electronic dampers and

 remote room sensors.  The

4-zone system is shown.

A01484

MODEL HUMCCLFP

HUMIDIFIER

By adding moisture to winter-dry 
air, a  Bryant humidifier can often 
improve comfort and keep 
furniture, rugs, and draperies in 
better condition. Moisturizing
household air also helps to retain 
normal body heat and provides 
comfort at lower temperatures.

C04009

A08153

ACCESSORIES

ELECTRONIC AIR CLEANER

(EAC)

Model EACB

AIR PURIFIER

Models GAPAAXBB1625, GAPAAXBB2025

MECHANICAL AIR CLEANER

Models EZXCAB, FILCAB

HUMIDIFIER

Model HUM

HEAT RECOVERY

VENTILATOR

Model HRV

ENERGY RECOVERY

VENTILATOR

Model ERV

UV LIGHTS

Model UVL

THERMOSTAT ---

NON---PROGRAMMABLE

For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover --- T6---NAC, T2---NAC
For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover --- T6---NHP---T2---NHP*
For use with 2---speed Air Conditioner --- deg. F/C, Auto Changeover --- T6---NRH*
For use with multi---use / stage configurations --- deg. F/C, Auto Changeover/Temperature and

Humidity Control --- T6---PRH

{

THERMOSTAT ---

PROGRAMMABLE

For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable ---

T6---PAC
For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable ---

T6---PHP*
For use with 2---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable ---

T6---PRH*
For use with 1---speed Air Conditioner --- deg. F/C, 5---2 Day Programmable --- T6---PAC
For use with multi---stage applications --- deg. F/C, Auto Changeover, 7---Day Programmable ---

T2---PHP

}

For multi---use / stage configurations --- deg. F/C, Auto Changeover, 7---Day Programmable/Tem-

perature and Humidity Control ---T6---PRH

{

ZONING CONTROL

Zone Perfect 3---Zone kit --- ZONEBB32AC01, ZONEBB32HP01

2---Zone Perfect Plus kit/Temperature and Humidity Control --- ZONEBB2KIT01---B
4---Zone Perfect Plus kit/Temperature and Humidity Control --- ZONEBB4KIT01---B
8---Zone Perfect Plus kit/Temperature and Humidity Control --- ZONEBB8KIT01---B

*Model HP and 2S thermostat must be field converted to air conditioner operation.

{

Thermidistat

t

Control can be configured for multiple use and staging. It must be configured for each specific application.

}

Dual Fuel thermostat is used with furnace and heat pump application.

313AA

V/

JA

V

Summary of Contents for 313AAV PLUS 80X

Page 1: ...onditioning Heating and Refrigeration Institute s standard coil only ratings when paired with selected Bryant evaporator coils STANDARD FEATURES S ECM blower motor included S Noise elimination combust...

Page 2: ...UAL RESET LIMIT SWITCHES GAS VALVE FLUE COLLECTOR BOX PRESSURE SWITCH INDUCER MOTOR ASSEMBLY CAPACITOR POWER CHOKE WHERE USED A02259 NOTE The 313AAV JAV Furnaces are factory shipped for use with natur...

Page 3: ...1 speed Air Conditioner deg F C Auto Changeover T6 NAC T2 NAC For use with 1 speed Air Conditioner deg F C Auto Changeover T6 NHP T2 NHP For use with 2 speed Air Conditioner deg F C Auto Changeover T6...

Page 4: ...PH X X X X X Combustible Floor Base KGASB0201ALL X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X Vent Extension Kit KGAVE0101DNH X X X X X Chimney Adapter Kit KGACA02014FC X X X X Chimney Adapter...

Page 5: ...Gas Maximum Inlet Pressure in wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft 610 M For elevations above 2000 ft 610 M reduce ratings 4 percen...

Page 6: ...lations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in single wall vent must be us...

Page 7: ...9 SEE NOTES 1 2 4 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL LEFT HORIZONTAL LEFT HORIZONTAL LEFT HORIZ...

Page 8: ...40 1065 1005 925 865 790 1 1280 1205 1140 1055 990 910 840 760 695 630 060135 Bottom or Side s 5 2295 2240 2185 2125 2070 2005 1925 1805 1670 1545 4 1725 1660 1605 1545 1460 1395 1340 1285 1230 1170 3...

Page 9: ...4 1 2 x 12 in 368 x 305 mm rectangle b For 1200 CFM 20 in 508 mm round or 14 1 2 x 19 1 3 in 368 x 491 mm rectangle c For 1600 CFM 22 in 559 mm round or 14 1 2 x 22 1 16 in 368 x 560 mm rectangle d Fo...

Page 10: ...in the horizontal position Line contact only permissible between lines formed by intersections of the Top and two Sides of the furnace jacket and building joists studs or framing DOWNFLOW POSITIONS D...

Page 11: ...V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES Connect Y terminal in furnace as shown for proper blower operation Some therm...

Page 12: ...________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard...