background image

1

Product Data

313AAV/JAV

Plus

80x

4--WAY MULTIPOISE

INDUCED--COMBUSTION GAS FURNACE

INPUT CAPACITIES: 45,000 THRU 135,000 Btuh

A08288

THE BRYANT

Plus

80x GAS FURNACE

The

Plus

80x Deluxe 4--Way Multipoise Gas Furnace offers

outstanding features in an 80% AFUE furnace.
Deluxe features include: an ECM motor which enhances SEER

performance up to 1.5 points*, a third fan relay for discrete

continuous fan speed, the ability to change continuous fan speeds
from the thermostat (Fan on

Plus

t

), dehumidify mode, standard

Media Filter Cabinet, fault code storage, and more. The

Plus

80x

is very quiet thanks to a new combustion design that eliminates

noise, rather than just muffle or box it in. Applications are easy
with 4--way multipoise design, through--the--furnace downflow

venting, 13 different venting options, and a door designed for easy

service access. An inner blower door is provided for tighter sealing
in sensitive applications. The 313AAV/JAV is approved for use in

Low NOx Air Quality Management Districts.
*as compared to the Air Conditioning Heating and Refrigeration

Institute’s standard coil--only ratings when paired with selected

Bryant evaporator coils.

STANDARD FEATURES

S

ECM blower motor included

S

Noise elimination combustion system

S

SmartEvap

t

can lower the humidity level in the home by

nearly 10%

S

Four--position furnace: Upflow, Horizontal Right,
Horizontal Left, Downflow

Thirteen different vent options

S

Compact design only 33--1/3 in. (847 mm) tall

S

High--Efficiency Media Filtration Cabinet included

S

Washable filter included

S

Microprocessor based “smart” control center

“Fan on

Plus

t

“--Continuous Fan speed adjustable from

thermostat
Adjustable heating air temperature rise
Dehumidify mode
LED diagnostics, non--volatile fault code memory, and self--test
feature
On--board fuse for transformer protection

S

Patented blocked vent safeguard to ensure proper furnace
venting

S

Insulated blower compartment

S

HYBRID HEAT

®

Dual Fuel System compatible

S

All models are chimney friendly when used with accessory
vent kit

S

Perfect Light

t

Igniter

S

Residential installations eligible for consumer financing
through the Comfort Credit Program

LIMITED WARRANTY

S

20--year warranty on Super S

t

heat exchanger

S

5--year parts warranty on all other components

Summary of Contents for 313AAV PLUS 80X

Page 1: ...onditioning Heating and Refrigeration Institute s standard coil only ratings when paired with selected Bryant evaporator coils STANDARD FEATURES S ECM blower motor included S Noise elimination combust...

Page 2: ...UAL RESET LIMIT SWITCHES GAS VALVE FLUE COLLECTOR BOX PRESSURE SWITCH INDUCER MOTOR ASSEMBLY CAPACITOR POWER CHOKE WHERE USED A02259 NOTE The 313AAV JAV Furnaces are factory shipped for use with natur...

Page 3: ...1 speed Air Conditioner deg F C Auto Changeover T6 NAC T2 NAC For use with 1 speed Air Conditioner deg F C Auto Changeover T6 NHP T2 NHP For use with 2 speed Air Conditioner deg F C Auto Changeover T6...

Page 4: ...PH X X X X X Combustible Floor Base KGASB0201ALL X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X Vent Extension Kit KGAVE0101DNH X X X X X Chimney Adapter Kit KGACA02014FC X X X X Chimney Adapter...

Page 5: ...Gas Maximum Inlet Pressure in wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft 610 M For elevations above 2000 ft 610 M reduce ratings 4 percen...

Page 6: ...lations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in single wall vent must be us...

Page 7: ...9 SEE NOTES 1 2 4 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL LEFT HORIZONTAL LEFT HORIZONTAL LEFT HORIZ...

Page 8: ...40 1065 1005 925 865 790 1 1280 1205 1140 1055 990 910 840 760 695 630 060135 Bottom or Side s 5 2295 2240 2185 2125 2070 2005 1925 1805 1670 1545 4 1725 1660 1605 1545 1460 1395 1340 1285 1230 1170 3...

Page 9: ...4 1 2 x 12 in 368 x 305 mm rectangle b For 1200 CFM 20 in 508 mm round or 14 1 2 x 19 1 3 in 368 x 491 mm rectangle c For 1600 CFM 22 in 559 mm round or 14 1 2 x 22 1 16 in 368 x 560 mm rectangle d Fo...

Page 10: ...in the horizontal position Line contact only permissible between lines formed by intersections of the Top and two Sides of the furnace jacket and building joists studs or framing DOWNFLOW POSITIONS D...

Page 11: ...V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES Connect Y terminal in furnace as shown for proper blower operation Some therm...

Page 12: ...________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard...