10
Table 1—Required Charge Adjustment for Indoor Coil Model -- HP
Furnace or Fan Coil Model Number
Outdoor Model Size
13
24B
25
36
37
48
60
CNPV*18**
---
/
/
/
/
/
/
CAP**18**
---
/
/
/
/
/
/
CNP**24
---
/
/
/
/
/
/
CNPV*19**
---
/
/
/
/
/
/
CAP**24
---
/
/
/
/
/
/
CSPH*24
---
/
/
/
/
/
/
CSPH*30**
/
/
/
/
/
/
/
F(E,V)4(A,B,C)NF002
+0.19
---
---
---
---
/
/
CAP**30
/
---
/
/
/
/
/
CNP**30
/
---
/
/
/
/
/
CNP**36
/
---
---
---
---
/
/
F(E,V)4(A,B,C)N(B,F)003
/
---
---
---
---
/
/
CAP**36
/
---
---
---
---
/
/
CNP**42
/
+.50
---
---
+.75
/
/
CAP**42
/
+.50
---
---
+.75
/
/
CSPH*36
/
/
---
---
+.75
/
/
CSPH*42**
/
/
+.75
+.75
+.75
/
/
CNP**31**
/
/
+.75
+.75
+.75
/
/
CNP**48
/
/
+.75
+.75
+.75
---
/
CSPH*48**
/
/
+.75
+.75
+1.00
---
/
CNP**37
/
/
/
/
/
/
/
CNP**43
/
/
/
/
/
/
/
CAP**48
/
/
/
+.75
+1.00
---
/
CNP**60
/
/
/
/
+1.00
---
---
CSPH*60
/
/
/
/
+1.00
---
---
F(E,V)4(A,B,C)N(B,F)005
/
/
+.75
+.75
+1.00
---
/
F(E,V)4(A,B,C)NB006
/
/
/
/
+1.00
+2.2
+1.00
CAP**60
/
/
/
/
/
+2.2
+1.00
CNP**61
/
/
/
/
/
/
/
/
= Comb. not allowed
---
= No charge adjust for ID
Table 2—Required Charge Adjustment for Indoor Coil Model -- AC
Furnace or Fan Coil Model Number
Outdoor Model Size
13
24B
25
36
37
48
49
60
CNPV*18**
---
/
/
/
/
/
/
/
CAP**18**
---
/
/
/
/
/
/
/
CNP**24
---
---
---
/
/
/
/
/
CNPV*19**
---
/
/
/
/
/
/
/
CAP**24
---
---
---
/
/
/
/
/
CSPH*24
---
---
---
/
/
/
/
/
CSPH*30**
/
---
---
/
/
/
/
/
F(E,V)4(A,B,C)NF002
+0.19
---
---
---
/
/
/
/
CAP**30
/
---
---
/
/
/
/
/
CNP**30
/
---
---
/
/
/
/
/
CNP**36
/
---
---
---
---
/
/
/
F(E,V)4(A,B,C)N(B,F)003
/
---
---
---
---
/
/
/
CAP**36
/
---
+.50
---
---
/
/
/
CNP**42
/
+.50
+.50
---
+.75
/
/
/
CAP**42
/
+.50
+.50
---
+.75
/
/
/
CSPH*36
/
+.50
+.50
---
+.75
/
/
/
CSPH*42**
/
+.50
+.50
+.75
+.75
/
/
/
CNP**31**
/
+.50
+1.25
+.75
+.75
/
/
/
CNP**48
/
+.50
+1.25
+.75
+.75
---
---
/
CSPH*48**
/
+.625
+1.25
+.75
+1.00
---
---
/
CNP**37
/
+.625
+1.25
+.75
+1.00
---
---
/
CNP**43
/
+.625
+1.25
+.75
+1.00
---
---
/
CAP**48
/
/
/
+.75
+1.00
---
---
/
CNP**60
/
/
/
/
+1.00
---
+0.125
---
CSPH*60
/
/
/
/
+1.00
---
+0.125
---
F(E,V)4(A,B,C)N(B,F)005
/
+.625
+1.25
+.75
+1.00
---
+0.125
/
F(E,V)4(A,B,C)NB006
/
/
/
+.75
+1.00
+1.5
+.625
+1.00
CAP**60
/
/
/
/
/
+1.5
+.625
+1.00
CNP**61
/
/
/
/
/
+1.5
+.625
+1.00
/ = Comb. not allowed
--- = No charge adjust for ID
Summary of Contents for 189BNV EVOLUTION