BRV ModvlvS Logico Installation And Operating Instructions Manual Download Page 4

Changes to the Unit

l

Changes, additions to or conversion of the unit are not permitted without written permission from the man-

ufacturer.

l

It is likewise forbidden to install additional components that have not been tested together with the unit.

l

If it becomes clear that safe operation of the unit is no longer possible, for example because of damage to the

housing, turn the Unit off immediately.

l

Any parts of the unit or accessories that are not in perfect condition must be exchanged immediately.

l

Use only original spare parts and accessories from the manufacturer.

l

Markings made on the unit at the factory must not be altered, removed or made illegible.

l

Only the settings described in these instructions may be set using the Unit.

Changes to the unit can compromise the safety and function of the unit or the entire system.

Warranty and Liability

The Unit has been manufactured and tested with regard to high quality and safety requirements. The warranty and liability shall
not include, however, any injury to persons or material damage that is attributable to one or more of the following causes:

l

Failure to observe these installation and operating instructions.

l

Improper installation, commissioning, maintenance and operation.

l

Improperly executed repairs.

l

Unauthorized structural changes to the unit.

l

Use of the device for other than its intended purpose.

l

Operation above or below the limit values listed in the ‚Specifications‘ section.

l

Force majeure.

Disposal and Pollutants

The unit conforms to the European RoHS 2011/65/EU for the restriction of the use of certain hazardous substances in electrical
and electronic equipment.

Under no circumstances may the device be disposed of with the normal household waste. Dispose of the unit only at
appropriate collection points or ship it back to the seller or manufacturer.

Description ModvlvS Logico

About the Controller

The Weather-controlled heating circuit regulator for heating systems ModvlvS Logico facilitates efficient use and function control
of your Heating system possible while its handling is intuitive. After every input step the suitable functions are matched to the keys
and explained in a text above. In the menu 'measurement values and settings' are help text and graphics in addition to key words.

The ModvlvS Logico can be used with different variants of installations, see " Hydraulic Variants " on page 6see “hydraulic vari-
ants” on page 1.

Important characteristics of the ModvlvS Logico are:

l

Depiction of graphics and texts using a lit display.

l

Simple viewing of the current measurement values.

l

Statistics and system monitoring by means of statistical graphics

l

Extensive setting menus with explanations.

l

Menu block can be activated to prevent unintentional setting changes.

l

Resetting to previously selected values or factory settings.

4

Summary of Contents for ModvlvS Logico

Page 1: ...Heating Controller ModvlvS Logico Weather compensated heating circuit controller Installation and operating instructions Read carefully before installation commissioning and operation 1...

Page 2: ...ference Actual 15 Reference Actual 16 Turn off HC 16 Buffer sensor 16 Mixer 16 Mixer run time 17 Signal type 17 PV contact 17 Mod Offset 17 Energy Saving Mode 17 Heating Circuit 2 17 Settings Domestic...

Page 3: ...cal Data The valid accident prevention regulations VDE regulations the regulations of the local power utility the applicable DIN EN stand ards and the installation and operating instruction of the add...

Page 4: ...nit l Use of the device for other than its intended purpose l Operation above or below the limit values listed in the Specifications section l Force majeure Disposal and Pollutants The unit conforms t...

Page 5: ...PWM output V1 V2 for 10 k working resistance 1 kHz level 10 V Terminal 24V voltage output Max load by external devices 24V 6W Max cable length VFS RPS sensors 3m CAN 3m at 3m a shielded twisted pair c...

Page 6: ...order l External relay for V1 V2 0 10V relay 1W 6A 77502 Hydraulic Variants The following illustrations should be regarded only as schematic representations of the respective hydraulic systems and do...

Page 7: ...rolling high efficiency pumps V2 0 10V PWM signal output e g for controlling high efficiency pumps S6 Temperature Sensor 6 outdoor 24V Power supply The connection of the ground wire is made at the low...

Page 8: ...istorted when screwed on 5 Using a drill and size 6 bit drill three holes at the points marked on the wall and push in the plugs 6 Insert the upper screw and screw it in slightly 7 Fit the upper part...

Page 9: ...the cable jacket must reach into the housing just to the other side of the strain relief Installing the Temperature Sensors The controller operates with Pt1000 temperature sensors which are accurate t...

Page 10: ...exit a menu If applicable a request for con firmation appears to save the made changes The function of the other 3 keys 4 is shown in the display right above the keys The right hand key generally has...

Page 11: ...on sumers connected and check the sensor values for plausibility Then set to automatic mode see Manual on page 14 The setup wizard can be accessed in menu 7 2 at any time Consider the explanations for...

Page 12: ...he right button changes the unit of time days and the two left buttons scroll through the diagram Operating hours Display of the operating hours of the consumers connected to the controller for exampl...

Page 13: ...cuit Day This menu is used to select the daytime mode times for the heating circuit three time periods can be specified for each weekday and copied to the following days Unspecified times are automati...

Page 14: ...14 days reference value program For the next 14 days you can enter the menu 4 temperatures for the next 14 days After 14 days the reference temperature of the 14th day is used continuously until the...

Page 15: ...ther room too hot In this case the slope of the curve should be reduced stepwise by 0 2 points and increases the day correction by 2 4 C each Night Correction Parallel characteristic translation The n...

Page 16: ...low values Example Reference room temp e g 25 C room temp e g 20 C 5 C Calculated reference temp e g 40 C room con troller 10 4 C 5 X 4 C 20 C Accordingly 20 C are added to the reference flow temperat...

Page 17: ...e technical description of your PV sys tem Mod Offset At modulated heat request the requested temperature can be increased by the value adjusted here Energy Saving Mode The Energy saving mode switches...

Page 18: ...the technical description of your PV sys tem 14 day Reference If operating mode 14 day reference value is selected see Operating mode on page 14 the reference flow temperature for each of the 14 days...

Page 19: ...offer any secure protection against legionella because the controller requires an adequate added amount of energy and the temperatures cannot be monitored in the entire storage area and the con nected...

Page 20: ...2 00 noon for 5 seconds to prevent seizing of the pump valve after long periods of inactivity ABS R X Activation daily weekly of the anti lock protection to a relay X at 12 00 for 5 seconds Frost Prot...

Page 21: ...or adjust it if desired Pressing esc more than once takes you back to the selection mode thus cancelling the commissioning help see Commissioning help on page 11 May only be started by a specialist du...

Page 22: ...ress of the data logger Auto Configuration DHCP If auto configuration is activated the data logger requests IP addresses and network parameters from a DHCP server that assigns an IP address subnet mas...

Page 23: ...tivated and can be used to make adjustments if necessary 1 Measurement values 2 Statistics 3 Times 8 Menu lock 9 Service values 9 Service values Serve for remote diagnosis by a specialist or the manuf...

Page 24: ...13 l Assess check plausibility of statistics see Serve for function control and long term monitoring of the system on page 12 l Check the error memory see Error messages on page 12 l Verify check plau...

Page 25: ...lude not only current measurement values and operating states but also all of the settings for the controller Write the service values down just once after commissioning has been successfully complete...

Page 26: ...eed a minimal voltage minimal signal PWM 0 10V on This voltage this signal requires the pump in order to turn on and to run at a minimum speed PWM 0 10V max With this value the maximum voltage level m...

Page 27: ...Technical data PWM and 0 10V Show signal Represents the set pump signal in a graphic and text overview 27...

Page 28: ...ation cannot be excluded Subject as a basic principle to errors and technical changes Date and time of installation Name of installation company Space for notes Your specialist dealer Manufacturer SO...

Reviews: