Technical data
and start-up
PDU254
18
5
Use and limits of the product
5.1
Proper use
The product PDU254 has been designed for the following uses, taking into consideration the limit values indicated
in chapter
5.2
:
Installation in a drive train for hybrid vehicles
Installation in a drive train for electric vehicles
Installation in a drive train for fuel cell vehicles
Use in high-performance motors (motor-racing sector)
Installation in a drive train for electric motorbikes
Installation in a drive train for utility vehicles (electric and hybrid)
Installation in a drive train for electric boats
Test bench applications
If the device is to be used for applications in areas other than those previously defined, the buyer is obliged to
coordinate these applications with the manufacturer and to obtain a written approval for these uses.
INFORMATION
This equipment is a custom built evaluation kit destined for professionals to be used solely at
research and development facilities for such purposes.
5.2
Improper use
Improper use is any use implemented under conditions which deviate from those indicated by the manufacturer in
their technical documents and data sheets. Taking into consideration the proper use indicated in chapter
5.1
, the
following limit values have been stipulated for the operation of the product PDU254. The product may not be used
outside these limit values. Operation outside these limit values can lead to life-threatening situations!
PDU254-A01
UNIT
Max. HV input voltage (operating voltage)
500
V
Min. ambient temperature
- 40
°C
Max. ambient temperature
+ 85
°C
Permissible peak current for a max. duration of 10 s
400
A
Max. permissible voltage drop via interlock loop
30
V