PROCEDURE STEP
ILLUSTRATION / OTHER INFORMATION
3.
Lead the HV cable (1) through the union nut (2).
Lead the HV cable (1) through the terminal insert (3).
4.
Place the terminal insert (1) with the front edge flush
with the cable insulation (2).
5.
Put the shielding braid (1) over the terminal
insert (2).
During this, the shielding braid (1) may overlap the
O-Ring (3) by a maximum of 2 mm.
Fix the terminal insert (2) in position on the HV
cable, eg with electrical tape (4).
You must absolutely make sure that the
individual strands of the shielding braid (1) do
not jut out over the sealing ring (3) under any
circumstances! Once in the integrated state, this
will lead to leakages and subsequently to the
leaking of water into the housing!