CAUTION

 

■ 

Please read this instruction manual carefully and understand the 
contents before starting the installation, connection (wiring), 
operation, and maintenance/inspection of this product. 

■ 

Ensure that this instruction manual is delivered to the end 
users who will actually use this product. 

■ 

Keep this instruction manual safe from loss until this 
product is discarded. 

■ 

This product is subject to change without prior notice.

 

 

Instruction Manual 

!

!

!

!

 

 

 

 

 

Published on October 1, 2017 

Shock Monitor 

 

Electric power detection type overload protector

 

Model No.:TSM4000H2 

 

TSM4000H2P 

Load Slaved Tracking Type

 

EHM40H206010R2 

TSUBAKI

TSUBAKI

TSUBAKI

TSUBAKIMOTO

MOTO

MOTO

MOTO

    

CHAIN

CHAIN

CHAIN

CHAIN

    

CO.

CO.

CO.

CO. 

Summary of Contents for TSM4000H2

Page 1: ...nd users who will actually use this product Keep this instruction manual safe from loss until this product is discarded This product is subject to change without prior notice Instruction Manual Publis...

Page 2: ...medium to light injury or property damage can occur Even if the instructions are followed a serious consequence may result depending on the situation Be sure to exercise due caution and follow all of...

Page 3: ...heck functions and operation periodically according to the instruction manual If any malfunction is found contact your dealer for repair Do not use the Shock Monitor in an atmosphere where any corrosi...

Page 4: ...ic power values can be output as analog voltage signals Output relay switching The output relay can be switched between Self Hold and Auto Reset Power detection response setting When the load pulsates...

Page 5: ...included as an accessory If this cable length is insufficient optional cables of 3 m 5 m 10 m 20 m and 30 m are available Contact TC when necessary 5 Part Names 5 Part Names 5 Part Names 5 Part Names...

Page 6: ...ult 7 Wiring 7 Wiring 7 Wiring 7 Wiring Complete wiring by using only the socket before attaching the Shock Monitor main unit to the socket Connect a commercial power supply of 90 to 250 VAC 50 60Hz o...

Page 7: ...through sensor Motor rated current A Sensor model No No of times to pass wire through sensor 0 1 0 71 TSM U010 6 0 36 TSM U010 12 0 2 1 4 TSM U010 3 0 70 TSM U010 6 0 4 2 3 TSM U010 2 1 2 TSM U010 3 0...

Page 8: ...way from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit and their outpu...

Page 9: ...minute current 10 mA or less is connected activate a relay for minute current with a relay output and then connect the contact of the relay for minute current to a sequencer photocoupler input 8 2 Co...

Page 10: ...sage Names Safety Installation Wiring Terminals Terminals Terminals Terminals Connection Operation Maintenance Inspection Specifications Dimensions Warranty 1 mA max 100 200 5 10 V 0 Load ratio Analog...

Page 11: ...class resistor TSM4 PR1 Contents Usage Names Safety Installation Wiring Terminals Connection Connection Connection Connection Operation Maintenance Inspection Specifications Dimensions Warranty This d...

Page 12: ...perational power supply Do not connect the secondary side of the inverter Contents Usage Names Safety Installation Wiring Terminals Connection Connection Connection Connection Operation Maintenance In...

Page 13: ...put relay Return to parameter 1 Show the Test Program mode switching screen Change to the Monitor mode Change to the Monitor mode Change the monitor screen Conduct the operation test of the relays Rel...

Page 14: ...ting values for High1 and High2 For power monitoring the displayed load ratio is a value calculated on the assumption that the selected motor capacity is 100 Turning on the operational power supply TS...

Page 15: ...applied PROGRAM MODE SET Contents Usage Names Safety Installation Wiring Terminals Connection Operation Operation Operation Operation Maintenance Inspection Specifications Dimensions Warranty The Hig...

Page 16: ...tor disables the relay output function for a specified period after it is started even in the Monitor mode Counting starts when the detected electric power reaches 5 or the current reaches 10 of the r...

Page 17: ...condition is cleared High2 5 to 200 Set the High2 output level Output is activated when the load ratio reaches or exceeds this setting value for the period specified at 8 Shock Time or longer 5 5 5 5...

Page 18: ...requency continues changing at the rate of 4 Hz or higher per second inhibit function is activated regardless of the inhibit time setting 2 Off The Auto Inhibit is disabled Reference value writing met...

Page 19: ...write the reference load ratio manually by pressing the and keys simultaneously while the motor is running Timing chart 1 4 1 4 1 4 1 4 L C D B a c k l i g h t L C D B a c k l i g h t L C D B a c k l...

Page 20: ...ay High1 indicator MIN 0 1s When parameter 6 is set to Auto Reset 12 Offset Mode 2 X1 Start Time Shock Time High1 Operating level tracking Reference value ON Shock Time RUN indicator High1 indicator H...

Page 21: ...o the actual load Model number of the current sensor Wrong Replace with a correct sensor Does the V phase motor wire pass through the current sensor Other phase U phase or W phase Install the wiring p...

Page 22: ...voltage test remove the Shock Monitor main unit from the socket to avoid test voltage 14 Periodic Inspection 14 Periodic Inspection 14 Periodic Inspection 14 Periodic Inspection 1 Inspect that the MO...

Page 23: ...Contact capacity 1c contact 250 VAC 0 5A Inductive load cos 0 4 30 VDC 0 4 A Inductive load 110 VDC 0 2A Inductive load Minimum load 24 VDC 4 mA Life 100 000 times of operation Analog output signal 0...

Page 24: ...0H2P TSM4 PR1 TSM4 PL1 37 46 4 45 54 5 63 5 20 8 C u r r e n t d i r e c t i o n m a r k Mounting hole 2 4 20 5 Mounting hole 4 6 C u r r e n t d i r e c t i o n m a r k Mounting hole R2 3 24 1 4 40 7...

Page 25: ...id warranty Even within the free warranty period if a failure or malfunction occurs in the TC product due to any of the following causes the investigation repair shall be charged 1 The customer did no...

Page 26: ...MEMO MEMO MEMO MEMO...

Page 27: ...MEMO MEMO MEMO MEMO...

Page 28: ...Ltd http tsubaki sg U S Tsubaki Power Transmission LLC http www ustsubaki com Taiwan Tsubakimoto Co http tsubakimoto com tw Tsubaki of Canada Limited http tsubaki ca Tsubakimoto Chain Shanghai Co Ltd...

Reviews: