8. Terminal
8. Terminal
8. Terminal
8. Terminal
Functions
Functions
Functions
Functions
8.1 Terminal block
Terminal
Description
[Power supply/ground]
● Power supply (Terminals 11 and 12)
・
Terminals used to connect the power supply for
the Shock Monitor.
Connect a commercial power supply of 90 to 250
VAC or a DC power supply of 90 to 250 VDC (no
polarity).
Never connect the output of an inverter or a servo
driver (which may cause breakdown).
● E (Terminal 10)
・
A noise filter is connected.
This terminal must be grounded.
This terminal must be grounded.
This terminal must be grounded.
This terminal must be grounded.
・
Leakage current of 0.5 mA at maximum will flow
the grounding wire from the power supply
through the capacitor inside the noise filter.
[Sensor cable connection]
・
Connector used to input the signals from the
current sensor.
CAUTION
CAUTION
CAUTION
CAUTION
To prevent noises, route the sensor cable at least
To prevent noises, route the sensor cable at least
To prevent noises, route the sensor cable at least
To prevent noises, route the sensor cable at least
15 cm away from an inverter, a servo driver unit,
15 cm away from an inverter, a servo driver unit,
15 cm away from an inverter, a servo driver unit,
15 cm away from an inverter, a servo driver unit,
and their output lines.
and their output lines.
and their output lines.
and their output lines.
[Voltage input]
●U, V, W (Terminals 1, 2, 3)
・
Terminals used to input the voltage applied to the
motor into the Shock Monitor.
When a 400 V class motor is connected, be sure to
connect the 400 V class resistor as shown on the
left.
Direct connection of a 400 V class motor may cause
breakdown.
A current of about 2 mA (AC) will flow through each
terminal.
20 19 18 17 16 15 14 13 12 11
C
o
n
te
n
ts
U
s
a
g
e
/N
a
m
e
s
S
a
fe
ty
In
st
al
la
tio
n
/W
ir
in
g
T
er
m
in
a
ls
T
er
m
in
a
ls
T
er
m
in
a
ls
T
er
m
in
a
ls
C
on
n
ec
tio
n
O
p
e
r
a
ti
o
n
M
ai
n
te
n
an
ce
/In
sp
ec
tio
n
Sp
ec
ifi
ca
tio
ns
D
im
en
si
on
s
W
a
r
r
a
n
ty
POWER
E
12
11
10
Noise
filter
TSM4000
1
2
3
U
V
W
2 mA
2 0 0 / 2 2 0 V A C
U
V
W
U
V
W
M
4 0 0 / 4 4 0 V A C
U
V
W
U
V
W
1
2
3
U
V
W
2 mA
M
4 0 0 V c l a s s
r e s i s t o r
T S M 4 - P R 1
T S M 4 0 0 0
T S M 4 0 0 0
Leakage
current
0.5 mA max.
Cu rren t sensor
Sen sor cab l e
3
4
1
2
16
19
18
17
TS M4 00 0
20
C-
-15V
+15V
C+
FG
!
!
!
!
Terminal block Nos.
Current sensor
Connection
prohibited
Power supply
Motor
voltage input
High2
output
High1
output
Ground
1
2
3
4
5
6
7
8
9
10
U
V
W
E
FG
C+ C-
+15 -15
Power