© 2013 Brunner GmbH
User manual IRON DOG 02 (1.1)
19
14 ERROR SEARCH
Error search
Possible cause
Background
Solution
Draught not available or not sufficient.
Outside temperature higher than indoor
temperature, or the chimney cover on the
roof is heated by the sun
Control chimney draught
Warming-up fire in the chimney
Wait until outside temperature is below
indoor temperature
Fuel unsuited
Wood logs are to big
Wood is damp or wet
Use dry and smaller wood
Without sufficient combustion air supply
bad igniting and flow
Control push rod position (Start-up position)
Control combustion air supply to the
installation area
Open fire door a little for a short time
Combustion air not sufficient
Minimum distance between ash layer in
the ash pan and bottom grate too small
Empty the ash pan
Fire burns weakly, much smoke, window becomes black
Possible cause
Background
Solution
Fuel unsuited
Wood logs are to big
Wood is damp or wet
Fire chamber temperature too low
Only dry wood gives high ignition
temperature with desired heat emission.
Combustion air not sufficient
Without sufficient combustion air supply
bad igniting and flow.
Control the position of the push rod
Weather or the situation of the chimney
influences the necessary exhaust of the
gases.
Check the chimney draught in general
In case of important disturbance, change
the chimney or install an exhaust gas
extractor
Creosote in or damage to the chimney
reduces the necessary draught.
Clean the chimney and the connection
pipes and examine them for tightness and
damage.
Draught not available or not sufficient
Check whether other stoves or fireplaces
are connected to the chimney.
The chimney draught can be worsened by
other connected fireplaces.