background image

Jun 2021

Whilst every effort has been made to ensure the accuracy of the information supplied. F.H. Brundle cannot be held responsible for any errors or omissions.  

This product must only be employed for its original intended use. Any other use is wrong and potentially dangerous. Installation must be carried out in full 

compliance with current regulations. F.H. Brundle cannot be held liable for any damages resulting from wrongful, erroneous or negligent use.

www.fhbrundle.co.uk

Tel. 01708 25 35 45

[email protected]

+

+

Page 2 of 2

The APS gate closer motor is factory set to close the gate in 5 – 7 seconds. There are 2 speed control valves. The one furthest 

from the pivot is for controlling the last 15 degrees of closing speed and is called the ‘Latching speed control valve’. The other 

valve is for controlling the speed of the first 75 degrees of closing.

Note: 

A ¼ turn can make a large difference to the speed of the gate. Do not turn screws more than 3 turns from the closed  

          position, if in doubt close off valves and start again. 

Turning the screw passed this point will result in oil loss. This           

         will cause the mechanism to fail, thus invalidating all warranties

Gate not closing fully: 

If the closer comes to its rest point before the gate is fully closed, release 2 x M10 nuts on bracket 

below closer, shut the gate and re-tighten the M10 nuts

1.  Using the key provided, turn both screws in until they stop turning. Be careful not to over tighten them once they have 

reached the limit of travel. Both valves are now closed and the gate will now not close or open

2.  Now undo the valve nearest the pivot 1 – 2 turns. This should result in the gate moving through the first 75 degrees of 

closing in about 6 seconds

3.  Next release the latching speed control valve 1 – 2 turns and the last 15 degrees of closing will take about 4 seconds

DETAILED SPEED CONTROL INSTRUCTIONS

CLOSING SPEED ADJUSTMENT

Closing speed

Final latching speed

To adjust, turn both screws clockwise 

until they stop. This means the gate will 

be locked into position. Then undo until 

they are the correct speed ensuring they 

do not turn more than 3 full turns from the 

stopped position.