BRUEL & KJAER 4511-W-006 Abbreviated Component Maintenance Manual Download Page 7

BN1100 Revision: 0

Initial Issue: 21/08/2012

ATA 31-10-04

Insulation Resistance

>100

Dielectric Strength

500 Vdc

Signal Ground

Isolated from housing

Connection

Through a bifilar cable (double-shielded recommended)

Single-shielded possible if connected to structure in both ends

Environmental Characteristics

Temperature Normal Operational Range

– 51°C  to +150°C  

Temperature Survival Range

– 55°C  to +150°C  

Max. Operating Sinusoidal Vibration

500 g

Max. Shock Level (peak)

(Max. Non-destructive Shock (peak))

±5000 g pk (half sine, 1 ms)

Humidity

Hermetically sealed

Physical Characteristics

Dimensions

See outline drawings in Fig. 2

Weight

<35 gram

Case Material

Stainless steel AISI 316–LS

Connector

GLENAIR type 8070-1072Z15-3CN

Mounting

Centre bolt 

Mounting Screw (optional accessory)

DIN 912 M4×18 (with safety wire hole)

According to SPX902A0002A01 

Environmental Constraints

According to DO160E

Marking

Supplier Name, NATO code, p/n, S/N, Date and Measurement axis (1)

Calibration chart

Acceptance test summary report

Included Deliverables

Certificate of conformance

All values are typical at 25°C unless measurement uncertainty is specified.

The document reference is online, please check the correspondence between the online documentation and the printed version.

Summary of Contents for 4511-W-006

Page 1: ...r el Kj r Sound Vibration Measurement A S All rights reserved No part of this publication may be reproduced or distributed in any form or by any means without prior written consent from Br el Kj r Sou...

Page 2: ...VALIDATION DES OPERATIONS DECRITES DANS CE MANUEL The maintenance operations described in this manual have been verified in the manufacturer s workshop by carrying out exactly dismantling reassembly t...

Page 3: ...ns 10 2 3 Procedure 10 Appearance 11 Transducer Sensivity Control 11 Electrical Test 12 SECTION 3 Disassembly 13 SECTION 4 Standard and Special Tools 14 4 1 Standard Tools 14 4 2 Special Tools 15 4 2...

Page 4: ...ronic charge converter enclosed in a hermetic housing The output provides a voltage signal proportional to the acceleration It is powered by a constant current line drive supply on the same wire as th...

Page 5: ...arge converter enclosed in a hermetic housing The output provides a voltage signal proportional to the acceleration for each axis It is powered by a constant current line drive supply on the same wire...

Page 6: ...0e 4 Hz ms 2 1 6e 4 Hz ms 2 Linearity 1 Transverse Sensitivity 5 max Temperature Response 10 15 max from 51 C to 150 C referring to sensitivity at 20 C Measurement Axis Perpendicular to the mounting...

Page 7: ...midity Hermetically sealed Physical Characteristics Dimensions See outline drawings in Fig 2 Weight 35 gram Case Material Stainless steel AISI 316 LS Connector GLENAIR type 8070 1072Z15 3CN Mounting C...

Page 8: ...Linearity 1 Transverse Sensitivity 5 max Temperature Response 10 max from 45 C to 125 C referring to sensitivity at 20 C Measuring Axes z axis perpendicular to the mounting surface x y z right hand co...

Page 9: ...Characteristics Dimensions See outline drawings in Fig 4 Weight 50 gram Case Material Stainless steel AISI 316 LS Connector GLENAIR type 8070 1072Z16 4CN Mounting 3 holes in isosceles triangle positio...

Page 10: ...4 for specification of overall dimensions 2 3 2 Transducer Sensitivity Control The transducer must be calibrated at a temperature around 25 C 5 C This calibration operation will not only test the tra...

Page 11: ...be Type 4511 W 006 Monoaxial 10 mV accelerometer sensitivity 10 ms2 gain of DMAU 8 Type 4524 W 001 Triaxial 100 mV accelerometer sensitivity 10 ms2 gain of DMAU 8 Note With Type 4524 W 001 Triaxial th...

Page 12: ...4 W 001 Triaxial use CCLD Power Supply WB 1453 and the cable supplied with it 4 Press the switch in battery position Read the level indicated on the meter the minimum is 23 V 5 Press the switch in bia...

Page 13: ...The transducer must not be disassembled or attempted to repair If there is a problem contact your Br el Kj r representative who may replace the transducer The document reference is online please chec...

Page 14: ...Special Tools 4 1 Standard Tools Standard tools are used for removal installation and connecting disconnecting The document reference is online please check the correspondence between the online docum...

Page 15: ...B 1453 to Type 4524 W 001 not shown Cable WL3428 included with CCLD Power Supply Connect WB 1372 to Type 4511 W 006 WB 3579 For verification of WB1372 cable not shown Reference resistance WB 3579 For...

Page 16: ...in battery position Read the level indicated on the meter the minimum is 23 V If level is under 23 V change the three 9V batteries inside the box Connect the resistance WB 3579 to the CCLD power suppl...

Page 17: ...31 10 04 Section 5 Consumables 9 V batteries 6 LR61 for CCLD Power Supply WB 1372 WB 1453 and Calibration Exciter Type 4294 The document reference is online please check the correspondence between th...

Page 18: ...unit is packed as above it must be stored in clean dry well ventilated premises free from corrosive fumes The temperature should be between 40 to 70 C and relative humidity between 20 and 85 The unit...

Reviews: