BRUEL & KJAER 4511-W-006 Abbreviated Component Maintenance Manual Download Page 18

18 of 18

Section 6

Cleaning, Storage and Transportation

Clean the accelerometer with a dry smooth cloth.

Store the equipment in a polythene bag, then in a cardboard box.

When  the  unit  is  packed  as  above,  it  must  be  stored  in  clean,  dry,  well-ventilated  premises  free  from  corrosive  fumes.  The 
temperature should be between –40 to +70°C and relative humidity between 20% and 85%. The unit should not be removed from 
its package during storage.

The document reference is online, please check the correspondence between the online documentation and the printed version.

Summary of Contents for 4511-W-006

Page 1: ...r el Kj r Sound Vibration Measurement A S All rights reserved No part of this publication may be reproduced or distributed in any form or by any means without prior written consent from Br el Kj r Sou...

Page 2: ...VALIDATION DES OPERATIONS DECRITES DANS CE MANUEL The maintenance operations described in this manual have been verified in the manufacturer s workshop by carrying out exactly dismantling reassembly t...

Page 3: ...ns 10 2 3 Procedure 10 Appearance 11 Transducer Sensivity Control 11 Electrical Test 12 SECTION 3 Disassembly 13 SECTION 4 Standard and Special Tools 14 4 1 Standard Tools 14 4 2 Special Tools 15 4 2...

Page 4: ...ronic charge converter enclosed in a hermetic housing The output provides a voltage signal proportional to the acceleration It is powered by a constant current line drive supply on the same wire as th...

Page 5: ...arge converter enclosed in a hermetic housing The output provides a voltage signal proportional to the acceleration for each axis It is powered by a constant current line drive supply on the same wire...

Page 6: ...0e 4 Hz ms 2 1 6e 4 Hz ms 2 Linearity 1 Transverse Sensitivity 5 max Temperature Response 10 15 max from 51 C to 150 C referring to sensitivity at 20 C Measurement Axis Perpendicular to the mounting...

Page 7: ...midity Hermetically sealed Physical Characteristics Dimensions See outline drawings in Fig 2 Weight 35 gram Case Material Stainless steel AISI 316 LS Connector GLENAIR type 8070 1072Z15 3CN Mounting C...

Page 8: ...Linearity 1 Transverse Sensitivity 5 max Temperature Response 10 max from 45 C to 125 C referring to sensitivity at 20 C Measuring Axes z axis perpendicular to the mounting surface x y z right hand co...

Page 9: ...Characteristics Dimensions See outline drawings in Fig 4 Weight 50 gram Case Material Stainless steel AISI 316 LS Connector GLENAIR type 8070 1072Z16 4CN Mounting 3 holes in isosceles triangle positio...

Page 10: ...4 for specification of overall dimensions 2 3 2 Transducer Sensitivity Control The transducer must be calibrated at a temperature around 25 C 5 C This calibration operation will not only test the tra...

Page 11: ...be Type 4511 W 006 Monoaxial 10 mV accelerometer sensitivity 10 ms2 gain of DMAU 8 Type 4524 W 001 Triaxial 100 mV accelerometer sensitivity 10 ms2 gain of DMAU 8 Note With Type 4524 W 001 Triaxial th...

Page 12: ...4 W 001 Triaxial use CCLD Power Supply WB 1453 and the cable supplied with it 4 Press the switch in battery position Read the level indicated on the meter the minimum is 23 V 5 Press the switch in bia...

Page 13: ...The transducer must not be disassembled or attempted to repair If there is a problem contact your Br el Kj r representative who may replace the transducer The document reference is online please chec...

Page 14: ...Special Tools 4 1 Standard Tools Standard tools are used for removal installation and connecting disconnecting The document reference is online please check the correspondence between the online docum...

Page 15: ...B 1453 to Type 4524 W 001 not shown Cable WL3428 included with CCLD Power Supply Connect WB 1372 to Type 4511 W 006 WB 3579 For verification of WB1372 cable not shown Reference resistance WB 3579 For...

Page 16: ...in battery position Read the level indicated on the meter the minimum is 23 V If level is under 23 V change the three 9V batteries inside the box Connect the resistance WB 3579 to the CCLD power suppl...

Page 17: ...31 10 04 Section 5 Consumables 9 V batteries 6 LR61 for CCLD Power Supply WB 1372 WB 1453 and Calibration Exciter Type 4294 The document reference is online please check the correspondence between th...

Page 18: ...unit is packed as above it must be stored in clean dry well ventilated premises free from corrosive fumes The temperature should be between 40 to 70 C and relative humidity between 20 and 85 The unit...

Reviews: