© Brüel & Kjaer Vibro GmbH/4 mm ds821 / 21.7.15 /technical specifications subject to change C104958.001/V02
l
34
EN
9.1.3
Extension cable type ds821.ec30x (optional)
1.
When stored or operated at a temperature of less than -30 °C, the IP65.
The PTFE protective conduit may only be used outside the potentially explosive area or, to prevent static charging,
must be fitted with a steel protective conduit or steel tube.securely connected to the local potential equalisation
(contact resistance ≤ 1 MΩ). The steel protective conduit or steel tube must be galvanically connected to the sensor housing.
2.
When used in hazardous areas, the ambient temperatures of the series ds822 ATEX must be observed,
view “Ambient temperature range” on page 22.
3.
When stored in original package
9.1.4
Driver (oscillator/demodulator) ds82x.od130
1.
When used in hazardous areas, the ambient temperatures of the series ds822 ATEX must be observed,
view “Ambient temperature range” on page 22.
2.
When stored in original package.
Length
4.0 m (-0 m / +0.8 m)
4.5 m (-0 m / +0.8 m)
9.0 m (-0 m / +1.6 m)
9.5 m (-0 m / +1.6 m)
Minimum bending radius
35 mm without cable protection
35 mm with steel protective conduit
75
mm with PTFE protective conduit
1
Connection
Plug at each end
Ambient conditions
Operating temperature range
2
-50 °C … +180 °C
Storage temperature range
3
-20 °C … +70 ° C
Electrical characteristics
Operating voltage (U
B
)
-24 V DC (-18…-28 V DC)
Current consumption
max. 12 mA (R
L
>= 100 kΩ)
Power supply
max. 1A and short-circuit proof
Source resistance dynamic
50 Ω
Mechanical characteristics
Housing material
Aluminium die cast (ADC 12)
Dimensions (WxHxD)
25 mm × 83 mm × 56 mm
Weight of the driver (oscillator/demodulator)
approx. 200 g
Connection
Socket
Ambient conditions
Degree of protection according to EN 60529
IP 20
Temperature
Operating temperature range
1
-35…+85 °C
Storage temperature range
2
-20…+70° C
Humidity
100 % non-condensing with protection of the plug connec-
tions and cable terminals
Altitude
> 2000 m
Polution degree
3 used in the protection of the connections and cable
clamps.