BRP-Rotax
MAINTENANCE MANUAL LINE
Table 3: Excess temperature up to max. 160 °C (320 °F) max. 15 min.
Step
Procedure
4
Check that oil lines are routed correctly and undamaged.
5
Cut oil filter housing and inspect filter mat for foreign matter.
6
Carry out oil change.
7
Inspect all further systems for correct functioning.
Exceeding over 160 °C (320 °F)
Table 4: Excess temperature over 160 °C (320 °F) and/or the operating limit for
longer than 15 min.
Step
Procedure
1
The whole oil system must be inspected, repaired or overhauled in accord-
ance with the BRP-Rotax instructions for continued airworthiness.
2
Inspect all further systems for correct functioning.
3
Carry out detailed inspection of the affected engine components.
4
The whole oil system (oil cooler, oil lines) must be inspected.
5
Cut oil filter housing and inspect filter mat for foreign matter.
6
Carry out oil change.
OIL PRESSURE BELOW MINIMUM VALUE
General note
ATTENTION
If the oil pressure falls below the minimum value, other limits are often exceeded,
e.g. the oil temperature. Please observe the relevant instructions.
NOTE
Any exceeding of the min. admissible oil pressure must be entered by the pilot in-
to the engine log book, stating duration extent of excessive pressure and pertinent
details.
Page 26
January 01 2020
Effectivity: 912 Series