8
INSTRUMENT PANEL CLEARANCES
Gauge Spacing (center to center)
• Minimum center distance - 4” (10.16 cm)
Instrument Panel Thickness
• Maximum panel thickness - 1” (2.54 cm)
Drilled Hole Size
IMPORTANT: Check space behind panel for adequate instrument clearance.
• 3 3/8 in. (86 mm)
FASTENING THE GAUGE
Insert instrument into panel hole. Install back clamp. Tighten nuts finger tight.
Electrical Connections
Connect the following:
• 2-pin deutsch connector to the warning horn (optional)
• 2-pin deutsch connector to the accessory power Y-connector
• the public network connector to the public network tee
For gauge connector identification, refer to
CONNECTOR IDENTIFICATION
.
TURNING THE DISPLAY ON
Turn the key switch to the On position or start the outboard to turn the display on.
NOTE:
There is no power button on this gauge.