Step 7: Install the dryer belt.

 

»

Turn both tension adjustment knobs counter-

clockwise to move the roller inward. This allows 

enough slack in the belt to loop around and 

complete the splice.

 

»

The belt should be fed so that it rests on the top of 

the dryer frame support channels.

 

»

Ensuring that the edges are even, connect the 

two ends together by interlocking the splice teeth 

and insert the splice wire completely through the 

splice.

 

»

Turn both tension adjustment knobs clockwise to 

move the roller out. Only adjust the pulley so that 

the belt is snug – do not overtighten.

Step 8: Venting is optional.  There is a vent section that 

provides a 10” hole for installation of an exhaust pipe.  The 

pipe can slide into the hole.  See Figure 4.

Step 9: Connect to power. See the attached wiring diagram.

Warning: This equipment is operated by high 

voltage electrical power and can be dangerous. 

Only a qualified electrician should connect 

and service this equipment. Safe and proper 

installation of this dryer is the customer’s 

responsibility.

Note: The wiring of the electrical supply to the 

dryer must be in accordance with all local, state, 

and national codes.

Warning: A 50Amp Branch Circuit Over-current 

Device is Required on supply power for this 

machinery.

The resistance heaters of your dryer operate on 208 to 

240 volts, single phase AC. Motors and control circuits 

operate on 115 volts AC. A four wire system providing 208-

240VAC electrical power, a neutral (common) for the 115 

volt system and a chassis ground is required.

Refer to the control panel wiring diagram accompanying 

these instructions. Check the following:

 

»

Connect the neutral (white) to the main terminal 

marked “N”.

 

»

Connect the copper or green ground to the chassis 

using the grounding lug.

 

»

Connect the main power supply wires to the main 

terminals marked “L1” and “L2”.

 

»

Ensure that 208-240 VAC is being delivered 

through the breaker by testing across these lines.

 

»

Ensure that 115VAC is being delivered between 

each of the power lines and the neutral line.

 

»

Main power lines should be rated to carry 125% of 

the full load amperes (FLA).

Machine Adjustments

Belt Tension

Apply enough tension to keep the belt from slipping on the 

roller. Excessive tension is unnecessary and may shorten 

the useful life of the belt.

Belt Tracking

Run the belt on high speed with the heat off to determine 

whether the belt is tracking correctly. The knobs in the 

end of the roller take-up plates are used to adjust the belt 

tension.

Belt tracking is adjusted with the knobs on the end of the 

conveyor frame. Increasing the belt tension on one side will 

cause the belt to track towards the opposite side of the dryer 

frame. Decreasing the belt tension on one side will cause 

the belt to track towards that side. Additional adjustments 

my be required when the oven reaches full temperature or 

as the belt stretches with wear.Temperature Display: This is 

the temperature currently being read in the heat chamber.

Baffle Height

The feed end of the oven features adjustable heat baffles.  

These can be lifted up and down manually after loosening 

the red knobs.  Set to the lowest height possible that the 

garments will still pass under the baffle.  Tighten the knobs 

when the baffle is at the desired height.

Proprietary Information of:

 

4661 Stafford Ave. S.W.

Wyoming, MI 49548

Tel. (616)249-0200

Fax. (616)249-3211

www.brownmfg.net

 

Unspecified Tolerances

x.xx  ± 0.010

x.xxx  ± 0.005

 

Remove all spatter, Burrs &

Break sharp edges.

ENG: 
DATE: 
SHEET:

Part Number : PR14450                           

Material:

  

Finish: 

1  of 1 

DAVID

11/30/2020

CRIMSON DRAGON 2430

97.500

50.159

33.141

32.125

35.120

POWER INPUT

BELT DIRECTION

ELECTRICAL SPECS

208V-240V

1 PH

32A

KNIGHT ENGINEERING DRAWING

POWER INPUT BOTTOM OF

CONTROL CABINET

Figure 4: Control panel layout

Summary of Contents for DragonAir DAK-2408

Page 1: ...rofits The new DragonAir line of curing systems is designed for water based digital printing in fast paced shops The Dragon Air Core Technology ensured consistent and complete curing on all garments Brown Manufacturing Group Inc 4661 Stafford SW Wyoming MI 49548 616 249 0200 fax 616 249 3211 www brownmfg net customerservice brownmfg net 20 00 March 2022 DAK 2408 ...

Page 2: ...tchet wrench 1 4 nut driver manual or powered screwdriver bit Step 1 Remove the feed end of the oven from the top of the machine Step 2 Remove the exit extension from the crate under the control panel Step 3 Remove the wooden securing board from undeer the machine using a powered screwdriver Remove the main body from the skid and place into desired position Place the machine into a stable location...

Page 3: ...supply wires to the main terminals marked L1 and L2 Ensure that 208 240 VAC is being delivered through the breaker by testing across these lines Ensure that 115VAC is being delivered between each of the power lines and the neutral line Main power lines should be rated to carry 125 of the full load amperes FLA Machine Adjustments Belt Tension Apply enough tension to keep the belt from slipping on t...

Page 4: ...t the furthest left dial position the fan is off At the first click the fan is full speed Turned to the right it is at it s lowest Recommendation is the dial is turned all the way to the right Step 4 Adjust the percentange of bump heat This adjusts the first heaters in the chamber with the goal of raising the shirt temperature quickly for faster cure This bump gets very hot 20 bump is suggested St...

Page 5: ...es are warranted for seven 7 years from the date of Installation iv Machine chassis are warranted for fifteen 15 years from the date of Installation frames rollers linear rails bearings gears plastic and metal with this Productpurchase WHAT IS NOT COVERED This warranty does not cover 1 Physical damage to thisProduct 2 Damage caused by improper Installation improper or abnormal use misuse neglect o...

Page 6: ...ble ZWIRE120 GND L1 L2 BKR3 ZBRKR101 D 3 4A BRD1 ZMTR111 Main Controller DC DC MOT1 ZGMTR113 Belt Motor External 4 18 2 MOT2 ZFAN100 B Control Panel Cooling Fan CONT2 ZCONT100 Fan Speed Control MOT3 ZFAN105 Convection Air Fan External 2 5 CONT3 ZCONT132 Temperature Control DC DC TCPL TCPL 17 16 SENSE1 ZSENSE102 Located in heater rack IR3 ZHTR101 2200W IR1 ZBULB133 C 1000W TR1 ZTRIAC101 Triac 21 20...

Page 7: ...lerances x xx 0 010 x xxx 0 005 Remove all spatter Burrs Break sharp edges ENG DATE SHEET Part Number PR14450 Material Finish 1 of 1 DAVID 11 30 2020 CRIMSON DRAGON 2430 97 500 50 159 33 141 32 125 35 120 POWER INPUT BELT DIRECTION ELECTRICAL SPECS 208V 240V 1 PH 32A KNIGHT ENGINEERING DRAWING POWER INPUT BOTTOM OF CONTROL CABINET ...