5.2 Preventative
Maintenance
The pump operating condition should be monitored on an ongoing basis. It is recommended
that amperage draw, discharge pressure and flow rate readings be recorded frequently to
identify any changes in the pump performance that could indicate possible problems with the
pump or motor.
If the pump amperage, discharge pressure and flow rate have a significant change then it is
recommended to remove the pump from service and complete a mechanical and electrical
inspection.
The motors seal leak detection moisture sensor system protects the motor from damage to the
motor components. If the Inboard Mechanical Seal fails, the moisture sensor system detects
the failure and shuts down the pump.
The motor thermostats protect the motor from damage to the motor components due to
overheating. If the thermostats detect a high temperature the pump will shut down.
5.3 Maintenance Tools and Equipment
HDS
50L / 75L / 100L - A
150L / 75M / 100M - A
200L / 150M / 200M - A
Allen Wrench
3/8”
1/2"
5/8”
Allen Wrench
3mm
3mm
5mm
Allen Wrench
4mm
4mm
8mm
Allen Wrench
10mm
14mm
14mm
Torque Wrench
1.7 – 221 lb-ft (2.3 kN – 300 Nm)
Box Wrench
1” (24mm)
2” (50mm)
Box Wrench
13/16” (20mm)
1-7/16 (36mm)
Anti Seize
Nickel Based
Loctite ®
262 High Strength
Grease Teflon
Grease
Summary of Contents for Vulcan Pumps HDS 100L
Page 4: ......
Page 38: ...AC Submersible Pump Motors Installation Operating Manual 4 09 MN414 ...
Page 39: ...Any trademarks used in this manual are the property of their respective owners ...
Page 41: ...Section 1 General Information ii Table of Contents MN414 ...
Page 50: ...Baldor District Offices ...