Establishing the Base -3
Step 4. Attach the metal bracket (5mm thick) to the galvanized pipe with a U-ring.
Step 5. Secure the Gateway mount kit to the galvanized pipe.
Step 6. Secure the antenna to the galvanized pipe by using the mount kit or the customized U-
ring.
Note: Please use a level to verify whether the antenna is vertically erected.
Step 7.
Insert the GPS antenna into a 1-inch PVC pipe. Then, use 1-inch U screws *2 to secure the
pipe to the pole.
Step 8. The antenna and RF cable connectors should be wrapped with electrical tape or covered
with waterproof materials to resist water penetration.
Step 9. Waterproof connectors should be used for connecting network cables.
Network cables
near the machine room should be wrapped with conduits, e.g. size 6 PVC cable protection hose.
Network cables and
RF cables
should be secured to avoid wind-induced vibrations.
Step 10.
The grounding wire that connects the lightning arrester to the gateway device should be
5.5mm
2
in diameter.
2’’
120°
16mm
70mm
500mm