background image

 

VOC 

Breath VOC concentration estimate  

Bits [15:0] 
 
 
 
 
Ref: 
BME680 – Datasheet 
V1.3 
Page 10 Table 5 
(July 2019) 
 

Conversion into breath-VOC equivalents in 
ppm concentration. 
The scaling is derived from lab tests with the 
b-VOC gas mixture described in Table 5. 

IAQ 

 

 
 
Indoor air quality (IAQ) 
classification 
 
 
 
Ref: 
BME680 – Datasheet 
V1.3 
Page 9 Table 4. 
(July 2019)  

Indoor-air-quality value as measured by digital sensor 

Bit [15:0]                          unsigned value range 0 – 500. 

 

Environment Temp 

Temperature as measured by digital sensor 

Bits [6:0] 
 
Bit [7] 

unsigned value 

τ

, range 0 – 127; 

temperature in °C = 

τ

 - 32. 

RFU 
measurement range -32 to 85°C 

 

 

 

 

© 2019 Browan Communications Inc. All rights reserved.

 

 

Summary of Contents for TBHV110-868

Page 1: ...Healthy Home Sensor IAQ Reference Manual TBHV110 915 TBHV110 868 ...

Page 2: ... 8 6 1 4 Model number 8 6 1 5 Factory check code 9 6 1 6 Model Name 9 6 2 PE Bag Back Label Label Barcode 9 7 Important Product Safety Instructions 10 8 Warnings 11 9 Notices 12 10 Cautions 12 11 Regulatory 13 Appendix Configuration Downlink Command 14 Appx 1 Configuration Command 14 Appx 1 1 Payload 14 Appx 2 Response Content 15 1 Description The Indoor Air Quality sensor utilizes LoRaWAN connect...

Page 3: ... 863 870MHz for EU 902 928MHz for North America Tx Power US 19dBm EU 17dBm Rx Sensitivity 135dBm Antenna Gain 2dBi Peak 5dBi Avg 2 4 Certifications and Conformity FCC ID 2AMUGTBSP100 IC 22980 TBSP100 CE ROHS REACH 2 5 Power Source 3 6V 1 2 AA Li SOCl2 1200mAh battery Maximum Voltage 3 6V Minimum Voltage 3 1V Current 135mA maximum 100uA minimum 2 6 User Interface LEDs One blue LED 2 7 Additional Fe...

Page 4: ...conditions or 5 minutes of inactivity The precise trigger values can be found in 4 1 1 4 Messages LoRaWAN Packets for this device use port 103 4 1 Status 4 1 1 Triggers Packet Triggers 5 minute inactivity 2 C delta environment temp 5 RH Delta 25 IAQ Index Delta The device will scan the environment every 5 minutes 4 1 2 Payload Port 103 Payload Length 11 bytes Bytes 0 1 2 3 4 5 6 7 8 9 10 Field Sta...

Page 5: ... V 25 ν 10 RFU Board Temp Temperature as measured by on board NTC Bits 6 0 Bit 7 unsigned value τ range 0 127 temperature in C τ 32 RFU measurement range 32 to 95 C RH Relative humidity as measured by digital sensor Bits 6 0 Bit 7 unsigned value in range 0 100 RFU eCO 2 CO2 equivalent estimate Bits 15 0 Estimation of the CO2 level in ppm The sensor does not directly measure CO2 but derives this fr...

Page 6: ...xture described in Table 5 IAQ Indoor air quality IAQ classification Ref BME680 Datasheet V1 3 Page 9 Table 4 July 2019 Indoor air quality value as measured by digital sensor Bit 15 0 unsigned value range 0 500 Environment Temp Temperature as measured by digital sensor Bits 6 0 Bit 7 unsigned value τ range 0 127 temperature in C τ 32 RFU measurement range 32 to 85 C 2019 Browan Communications Inc ...

Page 7: ...ry or battery pack subjected to extremely low air pressure may also result in an EXPLOSION or leakage of flammable liquid or gas Discard used batteries according to the manufacturer s instructions CAUTION The unit is provided with a battery powered circuit There is a danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufact...

Page 8: ...ers long 6 1 2 JoinEUI 900MHz 58A0CB0000210000 US AU AS923 BR 800MHz 58A0CB0001500000 EU IN RU Uses a hexadecimal representation resulting in 16 characters 6 1 3 DevEUI 58A0CBFFFFFEFFFF Uses a hexadecimal representation resulting in 16 characters 6 1 4 Model number Non reserved characters except and space with a maximum length of 20 characters 2019 Browan Communications Inc All rights reserved 7 ...

Page 9: ... Label Barcode PE Bag Label Back Label Definition of Back Label and PE Bag Barcode Label GS1 DataMatrix The GS1 Application Identifier 21 indicates that the GS1 Application Identifier data field contains a serial number The GS1 Application Identifier 92 assigned to the company s internal information is DevEUI 2019 Browan Communications Inc All rights reserved 8 ...

Page 10: ...ld Do not allow children or pets to play with products Observe proper precautions when handling batteries Batteries may leak or explode if improperly handled Observe the following precautions to avoid a sensor explosion or fire Do not drop disassemble open crush bend deform puncture shred microwave incinerate or paint the sensors Hub or other hardware Do not insert foreign objects into any opening...

Page 11: ...ry leaking do not allow the liquid to come in contact with the skin or eyes If contact has been made wash the affected area with copious amounts of water and seek medical advice Do not use any charger other than that specifically provided for use with the equipment Observe the plus and minus marks on the battery and equipment and ensure correct use Do not use any which is not designed for use with...

Page 12: ...oducts Do not use detergent or abrasive materials to clean the Tabs products as this may damage the sensors 10 Cautions CAUTION Disposal of a battery or battery pack into a fire or a hot oven or mechanically crushing or cutting of a battery or battery pack can result in an EXPLOSION Leaving a battery or battery pack in an extremely high temperature surrounding environment that can result in an EXP...

Page 13: ...n For the full FCC IC Compliance Statements and EU declaration of conformity visit www browan com Contact This symbol means that according to local laws and regulations your product should be disposed of separately from household waste When this product reaches its end of life take it to a collection point designated by local authorities Some collection points accept products for free The separate...

Page 14: ...e range 0 100 0x02 Set RH delta default value 5 RH value range 0 100 0x03 Set IAQ index delta default value 25 value range 0 255 Config Configuration 0 1 bytes See the table as follows Cmd Command Description Config Length 0x00 1byte Get Sensor Configuration Only for unconfirmed downlink 0 bytes 0x00 1byte Set keep alive value 1 bytes 0x01 1byte Set temperature delta 1 bytes 0x02 1byte Set RH delt...

Page 15: ...H 03 32 Set IAQ index delta 0x32 50 Appx 2 Response Content Only for unconfirmed downlink Port 204 Payload Length 8 bytes Payload Content Response content Ex 000C 0102 0205 0319 00 0C Keep alive interval 0x0C 12 5 min 60 min per unit 5 min 01 02 Temperature delta 0x02 2 C 02 05 RH delta 0x05 5 RH 03 19 IAQ index delta 0x19 25 2019 Browan Communications Inc All rights reserved 14 ...