WSW34
(Function setting 12
)
Selector
No.
Function
Setting and Specifications
1
|
3
Erasing time length of ICM tone
recorded preceding the tone
detection starting point in the case
of automatic line disconnection
due to no voice signal received
No. 1
2
3
0
0
0
:
0 sec.
0
0
1
:
1 sec.
0
1
0
:
2 sec.
0
1
1
:
3 sec.
1
0
0
:
4 sec.
1
0
1
:
5 sec.
1
1
0
:
6 sec.
1
1
1
:
7 sec.
4
5
No. of CNG cycles to be detected
(when the line is connected via the
external telephone in the external
TAD mode or via the facsimile
equipment in F/T or TAD mode)
No. 4
5
0
0
:
0.5
(A)
0
1
:
1
(B)
1
0
:
1.5
(C)
1
1
:
2
(D)
6
7
Number of DTMF tone signals for
inhibiting the detection of CNG
during external TAD operation
No. 6
7
0
0
:
3
0
1
:
2
1
0
:
1
1
1
:
OFF
8
CNG detection when the external
telephone is connected with a line
TAD mode
0: Only when the
1: Always
equipment detects
itself being called
NOTE:
Selectors 1 through 3 are applicable to those models equipped with a built-in TAD.
l
Selectors 1 through 3: Erasing time length of ICM tone recorded preceding the tone detection
starting point in the case of automatic line disconnection due to no voice
signal received
If the equipment has disconnected the line after detection of disconnection tone in ICM recording,
it erases tone recorded preceding the tone detection starting point for the time length set by these
selectors.
l
Selectors 4 and 5: No. of CNG cycles to be detected
The equipment interprets a CNG as an effective signal if it detects a CNG signal by the number of
cycles specified by these selectors in any of the following cases:
•
when the line is connected via the external telephone in the external TAD mode.
•
when the line is connected via the facsimile equipment in F/T or TAD mode.
l
Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during external
TAD operation
If the equipment receives this specified number of DTMF tone signals during external TAD
operation, it will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.
l
Selector 8:
CNG detection when the external telephone is connected with a line in TAD
If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself being
called. If the external telephone is connected with a line before the equipment detects itself being
called, the equipment will not longer detect a CNG signal.
If this selector is set to"1," the equipment will detect a CNG signal every time the external
telephone is connected with a line, even without detecting itself being called.
Summary of Contents for MFC-9050
Page 5: ...CHAPTER I GENERAL DESCRIPTION ...
Page 8: ...I 2 ...
Page 17: ...CHAPTER II INSTALLATION ...
Page 18: ...CONTENTS 1 INSTALLING THE UPDATE DATA TO THE FACSIMILE EQUIPMENT II 1 ...
Page 21: ...CHAPTER III THEORY OF OPERATION ...
Page 23: ...III 1 1 OVERVIEW Not provided on the FAX 8250P MFC 9050 ...
Page 33: ...III 11 Not provided on the FAX 8250P MFC 9050 Location of Sensors and Actuators ...
Page 36: ...III 14 ...
Page 38: ...III 16 European versions ...
Page 42: ...CHAPTER IV DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 48: ...IV 4 n n Disassembly Order Flow ...
Page 78: ...IV 34 Setting up the main PCB after replacement ...
Page 90: ...IV 46 2 Control panel locks 3 Scanner frame ASSY and separation roller gear ...
Page 91: ...IV 47 4 Top cover lock spring 5 Gear drive unit ...
Page 92: ...CHAPTER V MAINTENANCE MODE ...
Page 99: ...V 6 Scanning Compensation Data List ...
Page 145: ...V 52 FAX2750 FAX 8250P MFC4350 MFC4650 MFC 9050 Key Button Entry Order 1 ...
Page 146: ...V 53 MFC6650MC MFC 9550 FAX 8050P Key Button Entry Order 2 ...
Page 151: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Page 174: ...July 98 5X5301 Printed in Japan ...
Page 198: ......
Page 199: ......
Page 200: ......