26
WSW23
(Communications setting)
Selector
No.
Function
Setting and Specifications
1
Starting point of training check
(TCF)
0: From the head of a series of zeros
1: From any arbitrary point
2
3
Allowable training error rate
No. 2 3
0 0
:
0%
0 1
:
0.5%
1 0
:
1%
1 1
:
2%
4
5
Decoding error rate for transmission
of RTN
No. 4 5
0 0
:
16%
0 1
:
14%
1 0
:
10%
1 1
:
8%
6
7
Not used.
8
Limitation of attenuation level
0: Yes
1: No
NOTE:
Selector 8 is not applicable to the French versions.
Selector 1:
Starting point of training check (TCF)
At the training phase of receiving operation, the called station detects for 1.0 second a training
check (TCF) command, a series of zeros which is sent from the calling station for 1.5 seconds to
verify training and give the first indication of the acceptability of the line.
This selector sets the starting point from which the called station should start counting those zeros.
If this selector is set to "0," the called station starts counting zeros 100 ms after the head of a series
of zeros is detected.
If it is set to "1," the called station starts counting zeros upon detection of 10-ms successive zeros
50 ms after the head of a series of zeros is detected. In this case, if the detection of 10-ms
successive zeros is too late, the data counting period will become less than 1.0 second, making the
called station judge the line condition unacceptable.
Selectors 2 and 3: Allowable training error rate
The called station checks a series of zeros gathered in training (as described in Selector 1)
according to the allowable training error rate set by these selectors. If the called station judges the
line condition to be accepted, it responds with CFR; if not, it responds with FTT.
Selectors 4 and 5: Decoding error rate for transmission of RTN
The facsimile equipment checks the actual decoding errors and then transmits an RTN according
to the decoding error rate (Number of lines containing an error per page ÷ Total number of lines
per page) set by these selectors.
Selector 8:
Limitation of attenuation level
Setting this selector to "0" limits the transmitting level of the modem to 10 dB.
This setting has priority over the settings selected by WSW02 (selectors 5 through 8) and WSW13
(selectors 5 through 8).
Summary of Contents for Laser MFC-4800
Page 5: ...CHAPTER 1 GENERAL DESCRIPTION ...
Page 16: ...CHAPTER 2 INSTALLATION ...
Page 21: ...CHAPTER 3 THEORY OF OPERATION ...
Page 23: ...3 1 3 1 OVERVIEW ...
Page 31: ...3 9 Location of Sensors and Actuators ...
Page 33: ...CHAPTER 4 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 39: ...4 4 Disassembly Order Flow ...
Page 44: ...4 9 6 Turn the ASF upside down then remove the registration sensor actuator ...
Page 86: ...4 48 2 Scanner drive unit 3 Separation roller ...
Page 87: ...4 49 4 Document feed roller ...
Page 88: ...CHAPTER 5 MAINTENANCE MODE ...
Page 95: ...5 6 Scanning Compensation Data List a b c d e ...
Page 102: ...5 13 Key Button Entry Order ...
Page 110: ...CHAPTER 6 ERROR INDICATION AND TROUBLESHOOTING ...
Page 140: ...FAX2800 FAX2900 FAX3800 MFC4800 FAX8070P MFC9030 MFC9070 Appendix 1 EEPROM Customizing Codes ...
Page 143: ...FAX2800 FAX2900 FAX3800 MFC4800 FAX8070P MFC9030 MFC9070 Appendix 2 Firmware Switches WSW ...
Page 190: ...A Main PCB 1 5 ...
Page 191: ...A Main PCB 2 5 ...
Page 192: ...A Main PCB 3 5 ...
Page 193: ...A Main PCB 4 5 ...
Page 194: ...A Main PCB 5 5 ...
Page 195: ...B NCU PCB U S A Canada ...
Page 196: ...B NCU PCB U K Norway Netherlands Finland Denmark Sweden ...
Page 197: ...B NCU PCB Germany France Belgium Switzerland Ireland Austria Spain Italy South Africa ...
Page 198: ...B NCU PCB Asia Oceania 1 2 ...
Page 200: ...C Control Panel PCB ...
Page 201: ...D Power Supply PCB 100 120V Low voltage power supply ...
Page 202: ...D Power Supply PCB 200 240V Low voltage power supply Europe ...
Page 203: ...D Power Supply PCB 200 240V Low voltage power supply Asia Oceania ...
Page 204: ...D Power Supply PCB High voltage power supply ...