![Brother Laser MFC-4800 Service Manual Download Page 117](http://html.mh-extra.com/html/brother/laser-mfc-4800/laser-mfc-4800_service-manual_53754117.webp)
6-6
Error Code
X X
(Hex.)
Error factor
( B9
Light emission intensity error of the LED array. )
( D5
The MODEM fails to complete the command transmission sequence. )
( E4
Out of recording paper. )
E6
Write error in EEPROM.
( E8
Data scanning error during transmission. )
( EA
Document removed in phase B.)
( F5
EOL not found in page memory transmission mode. )
( F6
PC interface error. )
Error codes in parentheses do not appear in the "MACHINE ERROR X X", since those errors are
displayed as messages described in "[ 1 ] Error messages on the LCD." In the maintenance mode
(Function code 82), those error codes may be displayed.
Summary of Contents for Laser MFC-4800
Page 5: ...CHAPTER 1 GENERAL DESCRIPTION ...
Page 16: ...CHAPTER 2 INSTALLATION ...
Page 21: ...CHAPTER 3 THEORY OF OPERATION ...
Page 23: ...3 1 3 1 OVERVIEW ...
Page 31: ...3 9 Location of Sensors and Actuators ...
Page 33: ...CHAPTER 4 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 39: ...4 4 Disassembly Order Flow ...
Page 44: ...4 9 6 Turn the ASF upside down then remove the registration sensor actuator ...
Page 86: ...4 48 2 Scanner drive unit 3 Separation roller ...
Page 87: ...4 49 4 Document feed roller ...
Page 88: ...CHAPTER 5 MAINTENANCE MODE ...
Page 95: ...5 6 Scanning Compensation Data List a b c d e ...
Page 102: ...5 13 Key Button Entry Order ...
Page 110: ...CHAPTER 6 ERROR INDICATION AND TROUBLESHOOTING ...
Page 140: ...FAX2800 FAX2900 FAX3800 MFC4800 FAX8070P MFC9030 MFC9070 Appendix 1 EEPROM Customizing Codes ...
Page 143: ...FAX2800 FAX2900 FAX3800 MFC4800 FAX8070P MFC9030 MFC9070 Appendix 2 Firmware Switches WSW ...
Page 190: ...A Main PCB 1 5 ...
Page 191: ...A Main PCB 2 5 ...
Page 192: ...A Main PCB 3 5 ...
Page 193: ...A Main PCB 4 5 ...
Page 194: ...A Main PCB 5 5 ...
Page 195: ...B NCU PCB U S A Canada ...
Page 196: ...B NCU PCB U K Norway Netherlands Finland Denmark Sweden ...
Page 197: ...B NCU PCB Germany France Belgium Switzerland Ireland Austria Spain Italy South Africa ...
Page 198: ...B NCU PCB Asia Oceania 1 2 ...
Page 200: ...C Control Panel PCB ...
Page 201: ...D Power Supply PCB 100 120V Low voltage power supply ...
Page 202: ...D Power Supply PCB 200 240V Low voltage power supply Europe ...
Page 203: ...D Power Supply PCB 200 240V Low voltage power supply Asia Oceania ...
Page 204: ...D Power Supply PCB High voltage power supply ...