![Brother Intelli FAX-2820 Service Manual Download Page 310](http://html.mh-extra.com/html/brother/intelli-fax-2820/intelli-fax-2820_service-manual_53734310.webp)
App.
4-54
Confidential
WSW50
(SDAA settings)
Selector
No.
Function
Setting and Specifications
1
2
Percentage voltage for
interpreting the external
telephone as being hooked up
(based on the network's
standard voltage) (Not used.)
No. 1 2
0
0
:
80%
0
1
:
90%
1
0
:
70%
1
1
:
No
detection
3
DC mask curve table to be
applied when the line is
connected (Not used.)
0: Apply the initial value specified by local
regulations
1: Apply table DC5 prepared specially
4
AC impedance to be applied
when the line is connected
(Not used.)
0: 600
Ω
termination
1: ZR
termination
5
6
Current control to be applied
immediately after
connection of the line
(Not used.)
No. 5 6
0
0
:
Standard
0 1 : Increase start-up current for
termination
1 0 : Fine current control for termination
1 1 : Not used. (equal to "0, 0")
7
8
AC voltage threshold for
detection of ring
(Not used.)
No. 7 8
0
0
:
19
V
0
1
:
11
V
1
0
:
25
V
1
1
:
31
V
NOTE:
WSW50 is applicable to models equipped with SDAA circuits.
NOTE:
The machine does not support the SDAA.
Selectors 5 and 6: Current control to be applied immediately after connection of the line (Not used.)
FAX models equipped with an SDAA circuit (on which an NTU chip is mounted) might not be
connected to a broad band line such as an ADSL (Asynchronous Digital Subscriber Line) in a
stable condition. If those models fail to connect to such a line, try to change the current control to
be applied immediately after connection of the line by using selectors 5 and 6.
If selectors 5 and 6 are set to "0" and "1," respectively, the SDAA draws more current, decreasing
the period required to terminate the current control. If they are set to "1" and "0," the SDAA finely
controls precision of the termination current against the voltage to approach nearer to the specified
DC curve that specifies the current vs. voltage characteristics of the network termination.
Selecting either control may solve an unstable connection problem.
Summary of Contents for Intelli FAX-2820
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS FAX 2820 2825 2910 2920 MFC 7220 7225N ...
Page 13: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 63: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 66: ...Confidential 4 2 Cover page sample End page sample ...
Page 67: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 136: ...Confidential 5 67 5 1 41 Harness Routing ...
Page 137: ...Confidential 5 68 ...
Page 138: ...Confidential 5 69 ...
Page 139: ...Confidential 5 70 ...
Page 140: ...Confidential 5 71 ...
Page 141: ...Confidential 5 72 ...
Page 142: ...Confidential 5 73 ...
Page 145: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 151: ...Confidential CHAPTER 7 CLEANING ...
Page 153: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 158: ...8 4 Confidential MFC 7220 7225N Menu Set key and keys Start key Stop Exit key ...
Page 161: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i ...
Page 172: ...8 18 Confidential Cover page sample End page sample ...
Page 180: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 317: ......
Page 318: ......
Page 321: ...February 05 SM FAX037 13 8X5A01 Printed in Japan ...