WSW07
(Dial tone setting 1)
Selector
No.
Function
Setting and Specifications
1
2
Dial tone frequency band
control
No. 1 2
0 0
: Narrows by 10 Hz
0 1
: Initial value
1 X : Widens by 10 Hz
3
Line current detection
(Not used.)
0: No
1: Yes
4
|
6
2nd dial tone detection level
(Z = 600
Ω
)
No. 4 5 6
0
0 0 : -21 dBm
0
0 1 : -24 dBm
0
1 0 : -27 dBm
0
1 1 : -30 dBm
1
0 0 : -33 dBm
1
0 1 : -36 dBm
1
1 0 : -39 dBm
1
1 1 : -42 dBm
7
Allowable instantaneous
interrupt during reception of
1st dial tone
0: 30 ms
1: 50 ms
8 Not
used.
NOTE:
Selectors 1, 2, 4 through 7 are not applicable in those countries where no dial tone or line
current detection is supported, e.g., U.S.A.
NOTE:
Selector 3 is not applicable to those models having no loop current detection function.
Selectors 1 and 2: Dial tone frequency band control
These selectors set the frequency band for the 1st dial tone and busy tone (before dialing) to be
detected.
This setting is effective only when selectors 1 through 3 on WSW05 are set to "1,1,1."
Selector 3: Line current detection (Not used.)
This selector determines whether or not to detect a line current before starting dialing.
Selectors 4 through 6: 2nd dial tone detection level
These selectors set the detection level of the 2nd dial tone.
Selector 7: Allowable instantaneous interrupt during reception of 1st dial tone
This selector sets the allowable instantaneous interrupt period that should be ignored during
reception of the 1st dial tone.
Summary of Contents for Intelli FAX-2820
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS FAX 2820 2825 2910 2920 MFC 7220 7225N ...
Page 13: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 63: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 66: ...Confidential 4 2 Cover page sample End page sample ...
Page 67: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 136: ...Confidential 5 67 5 1 41 Harness Routing ...
Page 137: ...Confidential 5 68 ...
Page 138: ...Confidential 5 69 ...
Page 139: ...Confidential 5 70 ...
Page 140: ...Confidential 5 71 ...
Page 141: ...Confidential 5 72 ...
Page 142: ...Confidential 5 73 ...
Page 145: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 151: ...Confidential CHAPTER 7 CLEANING ...
Page 153: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 158: ...8 4 Confidential MFC 7220 7225N Menu Set key and keys Start key Stop Exit key ...
Page 161: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i ...
Page 172: ...8 18 Confidential Cover page sample End page sample ...
Page 180: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 317: ......
Page 318: ......
Page 321: ...February 05 SM FAX037 13 8X5A01 Printed in Japan ...