![Brother HL-B2080DW Service Manual Download Page 207](http://html.mh-extra.com/html/brother/hl-b2080dw/hl-b2080dw_service-manual_53670207.webp)
5-23
Confidential
Version information check
(1) Press the [
▲
] or [
▼
] in the initial state of maintenance mode to display “MAINTENANCE
57” on the LCD, and press the [OK]. “IC_ACT ALL” is displayed on the LCD.
(2) Press the [
▲
] or [
▼
] to display “5” on the LCD, and press the [OK]. “IC_VER BLACK” is
displayed on the LCD.
(3) Press the [OK]. Perform the destination check. If it is compatible, “IC_VER **” is
displayed on the LCD. (“**” indicates the version information) If it is not compatible, an
error in the
table on the previous page is displayed on the LCD.
Continuity (contact) check
(1) Press the [
▲
] or [
▼
] in the initial state of maintenance mode to display “MAINTENANCE
57” on the LCD, and press the [OK]. “IC_ACT ALL” is displayed on the LCD.
(2) Press the [
▲
] or [
▼
] to display “0” on the LCD, and press the [OK]. “IC_TX BLACK” is
displayed on the LCD.
(3) Press the [OK]. Perform the destination check. If it is compatible, “IC_TX OK” is
displayed on the LCD. If it is not compatible, an error in the
table on the
previous page is displayed on the LCD.