5. OPERATION
28
5. OPERATION
5-1. Part names and functions
(1) POWER indicator
(2) Warning indicator
(3) RESET key
(4) Cutter on indicator
(5) CUTTER ON key
(6) Program number LED
(7) Program No. UP key
(8) Program No. DOWN key
(9) Automatic mode indicator
(10) Test feed mode indicator
(11) Manual mode indicator
(12) Program mode indicator
(13) SELECT key
(14) Parameter display LED
(15) Parameter UP key
(16) Parameter DOWN key
(17) ENTER key
NOTE:
The following symbol is used on the operation panel. This symbol has a different meaning from the
meaning which is given in the "SAFETY INSTRUCTIONS" on p.i.
· · · · Notification of a machine problem
(1) POWER indicator
•
The POWER indicator (1) illuminates when the power is turned on.
(2) Warning
indicator
•
Illuminates when an error occurs, and after the RESET key is pressed to lower the work clamp but the
needle is not at the up stop position when the machine pulley turns.
•
This indicator also illuminates as a warning when a dangerous situation occurs, such as if the
machine is connected to a high-voltage power supply by mistake.
NOTE:
•
The sewing machine will not operate when the treadle is depressed while the warning indicator is
illuminated.
(3) RESET
key
•
Used to reset errors, and to raise and lower the work clamp.
(4) Cutter
on
indicator
•
When this indicator is illuminated, the cutter operates during automatic sewing. When it is switched
off, the cutter does not operate during automatic sewing.
(5) CUTTER ON key
•
This key is used to turn cutter operation during automatic mode, test feed mode, manual mode and
program mode on and off. When cutter operation is turned on, the cutter on indicator illuminates.
(6) Program number LED
•
Displays the program number in automatic mode, test feed mode and manual mode. Displays the
parameter number in program mode.
(7) Program No. UP key
•
Increases the program number by one in automatic mode, test feed mode and manual mode.
Increases the parameter number by one in program mode.
(8) Program No. DOWN key
•
Decreases the program number by one in automatic mode, test feed mode and manual mode.
Decreases the parameter number by one in program mode.
(9) Automatic mode indicator
•
Illuminates during automatic mode. The normal sewing mode is when the automatic mode indicator is
illuminated.
(3)
(3)
(6)
(7)
(8)
(4)
(5)
(13)
(17)
(15)
(16)
(14)
2099Q
(9)
(10)
(11)
(12)
(2)
(1)