IV-9
2.2.2
Mounting the outside frame unit in the Duplex unit
(1)
Keeping the inside frame unit slantwise, mate the hole for the fulcrum shaft L of
the inside frame unit with the fulcrum shaft L.
Note1 : Do not get the relay harness assy caught between the inside
frame unit and the outside frame unit.
Note2 : If the solenoid assy harness is slack, stretch it.
(2)
Turn the inside frame unit on the fulcrum shaft L to set it in the outside frame unit.
Figure 4.17
(3)
Insert one end of the fulcrum spring in the hole in the outside frame unit.
Figure 4.18
Solenoid assy harness
Solenoid
Outside frame unit
Relay harness assy
Fulcrum shaft L
Hole for the fulcrum shaft L
Inside frame unit
Inside frame unit
Fulcrum spring
Hole in the outside frame unit
Outside frame unit