2-62
Confidential
■
The entire image is light
<User Check>
- Check if the recording paper used is according to specifications.
- Check whether the paper type setting is correct.
- Carry out head cleaning.
- Replace the ink cartridge.
Step
Cause
Solution
1
Maintenance unit stained
Clean the maintenance unit.
(Refer to
Section 4.3.2 in this chapter
)
2
The head property value is
incorrect
Enter the head property value.
(Refer to
)
3
Head calibration not performed
Perform head calibration.
(Refer to
4
Non-discharge of ink from head
Carry out the recommended purge procedures. Refer
to "Recommended purge procedures" in
Section 1.3.29 "Purge Operation (Maintenance mode
76)".
5
Carriage PCB defective
Replace the carriage PCB ASSY.
6
Maintenance unit defective
Replace the maintenance unit.
7
Head defective
Replace the head/carriage unit.
8
Main PCB defective
Replace the main PCB ASSY.
Summary of Contents for DCP-J552DW
Page 120: ...3 3 Confidential 2 PACKING 3_002 ...
Page 127: ...3 10 Confidential 2 CIS flat cable 3_011 CIS flat cable Cable guide Cable guide Flat core ...
Page 220: ...4 10 Confidential ADF Copy Chart C A B D ...
Page 244: ...5 12 Confidential Scanning Compensation Data List ...
Page 246: ...5 14 Confidential Test Pattern ...
Page 254: ...5 22 Confidential MFC J450DW J470DW J475DW MFC J650DW J870DW J875DW ...
Page 270: ...5 38 Confidential pfadj1 Pattern ...
Page 271: ...5 39 Confidential pfadj2 Pattern ...
Page 272: ...5 40 Confidential pfadj3 Pattern ...
Page 278: ...5 46 Confidential Vertical Lines Check Pattern ...
Page 279: ...5 47 Confidential Ruled Lines Check Pattern ...
Page 283: ...5 51 Confidential Margin Check Pattern ...
Page 284: ...5 52 Confidential Margin Check Pattern ...
Page 314: ...6 3 Confidential Power supply PCB 100 V series ...
Page 315: ...6 4 Confidential Power supply PCB 200 V series ...
Page 329: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...