5-31
Confidential
(3) Enter the telephone number of the receiver machine and press the [Set] or [OK] key again.
(4) The machine displays the "ACCEPTED" for approx. two seconds and starts dialing to transfer
data.
Note
• Be sure to type the telephone number with the numerical keys. No auto-dial numbers
stored in memory can be used in this procedure.
• No station ID will be attached. A cover page and end page as shown below will be
automatically attached, instead.
Cover page sample
End page sample
JOB number for identification
Total number of pages to be transferred
Station ID registered in the sender FAX
FAX number of the sender
Telephone number of the sender equipment
Transfer start date
Model code
Boot ROM info
ROM info of program administration department
ROM info
Serial number
JOB number for identification
Total number of pages to be transferred
Station ID registered in the sender FAX
FAX number of the sender
Telephone number of the sender equipment
Error code
Summary of Contents for DCP-J552DW
Page 120: ...3 3 Confidential 2 PACKING 3_002 ...
Page 127: ...3 10 Confidential 2 CIS flat cable 3_011 CIS flat cable Cable guide Cable guide Flat core ...
Page 220: ...4 10 Confidential ADF Copy Chart C A B D ...
Page 244: ...5 12 Confidential Scanning Compensation Data List ...
Page 246: ...5 14 Confidential Test Pattern ...
Page 254: ...5 22 Confidential MFC J450DW J470DW J475DW MFC J650DW J870DW J875DW ...
Page 270: ...5 38 Confidential pfadj1 Pattern ...
Page 271: ...5 39 Confidential pfadj2 Pattern ...
Page 272: ...5 40 Confidential pfadj3 Pattern ...
Page 278: ...5 46 Confidential Vertical Lines Check Pattern ...
Page 279: ...5 47 Confidential Ruled Lines Check Pattern ...
Page 283: ...5 51 Confidential Margin Check Pattern ...
Page 284: ...5 52 Confidential Margin Check Pattern ...
Page 314: ...6 3 Confidential Power supply PCB 100 V series ...
Page 315: ...6 4 Confidential Power supply PCB 200 V series ...
Page 329: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...