MagnaTran 7.1 User’s Manual
Command Reference
MN-003-1600-00
Request Communication
Brooks Automation
Revision 2.2
8-71
Request Communication
Purpose
This command is used to display the serial communications and command execution
modes.
Format
RQ COMM [([M/B|FLOW|LF|ECHO|CHECKSUM|DREP|ERROR
LEVEL|BAUD RATE)]
Response
COMM mode flow linefeed echo chksum data_rep errorlevel baudrate
Arguments
ALL:
Reports all options in the order presented in the command format.
mode:
Reports the serial I/O communications mode.
MON Monitor mode (: )
PKT
Packet mode (_RDY)
flow:
Reports the command execution type.
SEQ
Sequential mode
BKG Background mode
BKG+ Background Plus mode
linefeed:
Reports the linefeed state.
ON
Linefeed enabled
OFF
Linefeed disabled
echo:
Reports the echo state.
ON
Echo enabled
OFF
Echo disabled
checksum:
Reports the checksum option state.
ON
Checksum enabled