13
11. Basic settings ex works
The basic settings ex work can be viewed and in some instances changed with the
following procedure:
When the unit is switched on, simultaneously press the "mod” (5) and "aux” (10) keys
for approx. 5 seconds (the LED array "prop” / "seq” / "dim” / "buz” / "slow” / "unit” blinks
to indicate that you are in the programming mode).
Additionally the LED of the "mod” (5) key is lit. The digital display (17) shows the
function number 0. The other function numbers can be selected by pressing the energy
control keys "up/down” (18).
By briefly pressing the "aux” key, the digital display shows the actual value respectively
the actual setting within the selected function number. The LED of the "mod” key does
not light up in this mode. Within the function numbers 1, 2, 3 and 9, the settings can be
changed with the energy control keys "up/down”.
Concerning the function numbers 0 and 4 – 8, the different pairs of these multiple digit
values can be shown by means of the energy control keys "up/down”.
Return to normal operation by pressing (1 s) the "aux” key, by switching the unit off and
on again or automatically after a period of 20 seconds.
Function number Meaning and possible settings
0
Program
version: Standard
display
Program number: after pressing the energy control "down" key
1
Control range flash energy:
Setting ex work: "off" (--).
Display "on" the control range of the flash energy is extended on
to 5 f-stops (10 - 5.0).
2
Sensibility of the photocell:
Setting ex work: "on"
This function reduces the sensibility of the photocell. If the function
is activated the digital display shows the value "off".
3
Definition function "ir/rf":
Setting ex work: digital display shows the value "3"
= IR receiver and RFS Interface (if available) activated.
Display value "1" = only IR receiver activated
Display value "2" = only RFS Interface activated.
4
Flash
counter:
Figure group in the display: xxxx
XX
= standard display
Figure group in the display: xx
XX
xx
= after pressing the energy control "up" key
Figure group in the display:
XX
xxxx
= after pressing the energy control "up" key
5
Series
number of the unit: Figure group in the display: xx
XX
6
Series
number of the unit: Figure group in the display:
XX
xx
7
Production
date of the unit:
Figure group in the display: xx
XX
= month