background image

5

1300 276 642

bromicrefrigeration.com.au

•  Read all instructions before installing or using this appliance.

•  Retain this manual for future reference.

•  Use this appliance only as described in this manual. Any other use not recommended by the manufacturer 

may cause fire, electric shock or injury. 

•  Improper installation, adjustment or alteration and failure to follow the warnings and instructions in this 

manual could result in severe personal injury, death or property damage.

•  The manufacturer is not responsible for any damage that could happen from improper use. The manufacturer 

emphasises that this appliance should be used in a responsible manner and that all procedures, warnings, 
and safety instructions contained in this booklet be followed strictly. 

•  Check for damage to the appliance regularly. If damage to the appliance is suspected, discontinue use 

immediately and contact the supplier or qualified person to repair.

•  This appliance is not intended for use by people (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible of their safety.

•  Keep packaging material out reach of children.

•  Children should be carefully supervised to ensure that they do not play with the appliance.

•  Do not attempt to alter the appliance in any manner.

•  Please pay attention to the maximum load limit when filling the baskets.

•  All work on electrical equipment must be carried out by a qualified and licensed technician only.

•  Do not perform maintenance until the appliance has been turned off and power disconnected.

•  Never detach any cover except where specifically instructed in this manual. Doing so might expose live 

electrical parts.

•  Do not operate the appliance with panels, covers or guards removed.

•  Keep the air intake and outlets free of obstructions.

•  Do not use the appliance outdoors.

•  If the supply cord becomes damaged, it must be replaced by an authorised service agent or similarly 

qualified person in order to avoid a hazard.

•  If the appliance has not been used, or will not be used for a long period of time, disconnect  

power supply.

•  Electrical equipment should not be placed under the unit or where refrigerant could gather in the event of a 

leak. 

•  Always use original spare parts supplied by the manufacturer

•  When contacting Bromic Customer Service, ensure that you have the Model, Serial Number available. The 

information can be found from the rating plate which is located outside the appliance. 

•  Unplug the appliance before cleaning or moving it to avoid electric shock. 

•  Never use steam cleaner or wet cloths to clean the control panel, lighting and vent grills. This may damage 

the appliance or cause electric shock. 

•  The power plug must be accessible at all times while the appliance is running. 

•  The power supply must be properly earthed, consult a qualified electrician if unsure. 

•  Do not use extension cord or power adapter with this appliance. 

•  Do not use this appliance in an area with high humidity or subject to water damag

e

2. IMPORTANT NOTES AND WARNINGS

Summary of Contents for MEDIFRIDGE MEDO220GD-NR

Page 1: ...Confidence and control 08 06 2022 INSTRUCTION MANUAL MEDIFRIDGE DISPLAY FRIDGE MEDO220GD NR MEDO374GD NR...

Page 2: ......

Page 3: ...This Installation operation and service manual may not be reproduced in any form with prior written consent from Bromic Refrigeration 1 PREFIX 4 2 IMPORTANT NOTES WARNINGS 5 3 PRODUCT OVERVIEW 7 4 INS...

Page 4: ...ict con trol Refer to the National Vaccine Storage Guidelines Strive for 5 for more information on vaccine storage and handling or contact your local state of territory health department https www hea...

Page 5: ...ing the baskets All work on electrical equipment must be carried out by a qualified and licensed technician only Do not perform maintenance until the appliance has been turned off and power disconnect...

Page 6: ...frigeration circuit becomes damaged Avoid open flames and other source of ignition Immediately disconnect the appliance from power supply Ventilate the room and call Service Hotline WARNING Leaking re...

Page 7: ...ated sheet metal Powder coated sheet metal Electrical Voltage V 240 240 Frequency Hz 50 50 Input Power W 235 350 Current A 1 18 1 23 Door Solid or Glass Low E Glass Argon Gas Low E Glass Argon Gas Sha...

Page 8: ...ll the appliance where it is exposed to warm draughts or open doors Keep the air intake and outlets free of obstructions Adequate allowance should be made for door openings Ventilation Ensure the foll...

Page 9: ...e is rated 70 C It is recommended that the cable should not come into contact with parts over 50 C Do not turn off power before consulting the person responsible Mark the power source clearly so the r...

Page 10: ...ed in The electronic controller will display the current cabinet temperature after the unit has been connected to the power supply The LED indicates that refrigeration circuit is operating During the...

Page 11: ...he maximum and minimum temperatures two 2 times a day Recordings should be taken before the first door opening of the day MIN Temperature i Press the arrow key ii The Lo message will be displayed foll...

Page 12: ...nimum Limit door opening durations to less than 30seconds Wait 10 minutes for product and cabinet temperature to stabilise before opening door again Ensure products and materials are between 2 and 8 C...

Page 13: ...the products and transfer to a suitable location prior to cleaning the inside of the cabinet Do not use any aggressive or abrasive cleaning agents Never use a water hose or a high pressure jet to clea...

Page 14: ...ventilation C Wall clearances below minimum distance D Dirty condenser coil E Ice build up on evaporator coil A Relocate unit B Keep ventilation slots free C Adjust to minimum clearance D Clean E Per...

Page 15: ...e and promoting re use of the high quality materials employed used commercial refrigeration equipment must be collected for expert disposal and recycling Therefore observe the following disposal regul...

Page 16: ...orage guidelines strive for 5 BROMIC CANNOT BE RESPONSIBLE FOR THE LOSS OF OR DAMAGE TO STOCK All Bromic products are manufactured to the highest quality standard and are supported by our Extra Care S...

Page 17: ...xample 1 SERVICE REQUEST PRIORITY A B PRIORITY A SERVICE PRIORITY B SERVICE SERVICE CALL PLACED BEFORE MIDDAY SERVICE CALL PLACED AFTER MIDDAY When the unit is NOT performing its primary function such...

Page 18: ...NOTES...

Page 19: ......

Page 20: ...Y HEAD OFFICE SHOWROOM BROMIC REFRIGERATION 10 Phiney Place Ingleburn Sydney NSW 2565 Australia T 1300 276 642 For further product information bromicrefrigeration com au BROMIC REFRIGERATION 10 Phiney...