background image

10

bromic.com

d

f

e

/ 9.1 "

870

/ 34.2"

c

/ 9.1 "

870

/ 34.2"

NOTE: The thickness of the ceiling surface dictates which locator 
hole to use. The fastening screws must be inserted into a strong 
non-combustible structural members that can easily support the 
weight of the heater. Your installation may require re-enforcing 
before the frame can be safely installed. 

3. Unscrew and remove the grey plug from the wall bracket. 
Attach the supplied metal cable gland 

(c)

 into the same hole 

from the outside of the bracket.

4. Feed heater power cable through cable gland (supplied) from 
inside of wall bracket

 (d)

.

5. Ensure M6x14mm screws are inserted into either side of heater 
bracket with 6mm (0.3”) of the threaded shaft exposed under the 
screw head. 

(e)

.

6. Insert heater bracket into mounting bracket by hooking M6 
screws into place in mounting slots

 (f)

.

7. Fix heater to bracket in straight position using M4x10mm 
positioning screws on either side of mounting bracket

 (g)

. Ensure 

M6 screws are sitting fully in the mounting slots (as if the heater 
were hanging from the wall bracket).

8. Fit the smaller, straight cover over the heater bracket so that 
the slots pass over the shafts of the M6x14mm mounting screws 

(h)

. Fit the larger cover over the smaller cover in the same way 

from the opposite side of the bracket

 (i)

.

9. Tighten mounting screws firmly, ensuring covers fit snugly 
against the bracket on all sides

 (j)

.

10. Firmly tighten cable gland in wall bracket so that cable does 
not move when pulled.

11. Attach the bracket end-cap to the wall bracket using the 

 

4 x M5 screws and nuts provided 

(k). 

12. Carefully remove the 4 x M5 screws fastening the heater 
mounting bracket to the back of the heater. Be careful not to 
move or put any force on the bracket. Place the 2 halves of the 
ceiling recess mounting plate over the screw holes. Re-insert the 
screws & tighten firmly. 

(l)

13. Make electrical connection from heater to power supply. This 
is described under ‘Electrical Installation’ on page 13.

 

14. Raise one long side of heater up into ceiling frame cavity & 
then raise whole heater into cavity. 

(m)

 

15. Rotate the heater into level position in the ceiling cavity 

(n)

 

and then lower down onto the ceiling frame . Ensure the heater 
brackets are hooked over the ceiling frame and sitting in the slots 
on both sides. 

(o)

g

h

i

/ 9.1 "

870

/ 34.2"

HEATING INSTALLATION INSTRUCTIONS

k

l

j

k

j

m

o

n

CEILING RECESS KIT INSTALLATION (SOLD SEPARATELY)

b

Summary of Contents for 2622000

Page 1: ...R SERIES II BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL IMPORTANT READ THIS MANUAL CAREFULLY SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR...

Page 2: ...ial use unless otherwise specified The marine grade variants shall be installed for land and The marine grade variants shall be installed for land and coastal environment application ONLY coastal envi...

Page 3: ...OVERVIEW 5 PRODUCT DESCRIPTION 5 SPECIFICATIONS 5 PRODUCT FEATURES 5 HEATER INSTALLATION INSTRUCTIONS 6 CEILING WALL MOUNTING 6 CEILING RECESS SOLD SEPARATELY 9 TUBE SUSPENSION SOLD SEPARATELY 11 ELE...

Page 4: ...e subjected to radiant heat and could be seriously damaged Combustible materials e g walls floors furniture fixtures and plants must be kept a minimum of 1000mm 3 ft from the heater Regularly inspect...

Page 5: ...for a complete version If you are unsure of any aspect of the installation contact Bromic for advice The Platinum Smart Heat Electric is designed to provide efficient spot heating for commercial and...

Page 6: ...otected MINIMUM DISTANCE BETWEEN HEATERS MEASURED FROM EDGE OF HEATER MUST BE AT LEAST 500mm 20 WARNING Standard Variants Standard Variants Ensure that the heating unit is not directly exposed to rain...

Page 7: ...s and stop water entering the bracket the mounting surface MUST be protected from the rain using the black gasket provided 4 Ensure M6x14mm screws are inserted into both sides of heater bracket with a...

Page 8: ...ket on all sides k k Straight bracket option j i h j h i k Angle bracket option 9 Fit the smaller cover over the heater bracket so that the slots pass over the shafts of the M6x14mm mounting screws i...

Page 9: ...cation Standard 4500W Marine 4500W Region AU NZ EU UK US CA AU NZ EU UK US CA Part Number 2623000 BH3623000 2623001 BH3623001 Material Brushed Stainless Steel 304 Brushed Stainless Steel 316 3500mm 11...

Page 10: ...bracket so that the slots pass over the shafts of the M6x14mm mounting screws h Fit the larger cover over the smaller cover in the same way from the opposite side of the bracket i 9 Tighten mounting...

Page 11: ...d Stainless Steel 304 Brushed Stainless Steel 316 Kit Description 23 62 600mm 47 24 1200mm 23 62 600mm 47 24 1200mm Part Number AU NZ 2620243 2620244 2020564 2020565 Part Number EU UK BH3130023 BH3130...

Page 12: ...esponsibility to assure that adjacent materials are protected MINIMUM DISTANCE BETWEEN HEATERS MEASURED FROM EDGE OF HEATER MUST BE AT LEAST 500mm 20 WARNING This heater MUST be permanently installed...

Page 13: ...D INSTALLATION INDIVIDUAL ELEMENT CONTROL WIRING DIAGRAM 4500W MODEL SINGLE PHASE 240V SUPPLY OPTIONAL INSTALLATION 4500W 240V 18 75A TOTAL FOR PART NUMBERS BH3622000 BH3622001 BH3622002 BH3622003 450...

Page 14: ...MODEL THREE PHASE Y 208V SUPPLY OPTIONAL INSTALLATION WIRING DIAGRAM 4500W MODEL THREE PHASE Y 208V SUPPLY STANDARD INSTALLATION INDIVIDUAL ELEMENT CONTROL 4500W 240V 18 75A TOTAL FOR PART NUMBERS BH...

Page 15: ...MAINTENANCE SERVICING WARNING Servicing and maintenance MUST be carried out by an authorised and licenced service person only Do not operate any heater after it malfunctions Disconnect power at servi...